Two dimensional ion temperature measurement by application of tomographic reconstruction to Doppler spectroscopy

Two dimensional ion temperature measurement by application of tomographic reconstruction to Doppler spectroscopy
复制标题

应用层析成像重建多普勒光谱进行二维离子温度测量

DOI:
10.1088/0029-5515/53/9/093027
复制
发表时间:
2013
期刊:
影响因子:
3.3
通讯作者:
et. al.
et. al.
中科院分区:
物理与天体物理1区
文献类型:
--
作者:
H. Tanabe;et. al.

文献摘要

相似文献

A novel 2D ion temperature measurement for toroidal plasmas has been developed by use of cost-effective discrete tomography reconstruction of 2D ion Doppler spectroscopy composed of a polychromator with an ICCD camera and optical fibres. The 2D projection of the line spectrum collected by 35 (7× 5) optical fibres is transformed into the r–z profile of the local spectrum by means of the Abel inversion at each wavelength and finally into the 2D (r–z) profile of the ion temperature. Numerical tests of its algorithm indicate that the reconstruction error for a peaked temperature profile is smaller than 15% if the chord-integrated signals have noise smaller than 5%. This system successfully measured the peaked ion temperature profile of a torus plasma on the r–z plane under the condition of negligibly small plasma flow.