Binary Concentration Shift Keying with Multiple Measurements of Molecule Concentration in Mobile Molecular Communication
Binary Concentration Shift Keying with Multiple Measurements of Molecule Concentration in Mobile Molecular Communication
复制标题
DOI:
10.1007/978-3-030-57115-3_4
复制
发表时间:
2020-07
期刊:
影响因子:
--
通讯作者:
Yutaka Okaie;T. Nakano
中科院分区:
文献类型:
--
作者:
Yutaka Okaie;T. Nakano
Binary concentration shift keying in molecular communication is a modulation technique that transforms binary information onto the concentration of molecules. Transmitter releases a pre-specified number of molecules into the environment according to the information it wishes to transmit to receiver. In this paper, we consider binary concentration shift keying in mobile molecular communication where a mobile receiver performs multiple measurements of molecule concentration to demodulate information that the transmitter transmits. Numerical experiments are conducted to evaluate the performance of mobile molecular communication with the binary concentration shift keying with multiple measurements of molecule concentration in terms of achievable information transmission rate.