Method comparison studies of telomere length measurement using qPCR approaches: A critical appraisal of the literature.
Method comparison studies of telomere length measurement using qPCR approaches: A critical appraisal of the literature.
复制标题
DOI:
10.1371/journal.pone.0245582
复制
发表时间:
2021
期刊:
影响因子:
3.7
通讯作者:
Drury S
中科院分区:
文献类型:
--
作者:
Lindrose AR;McLester-Davis LWY;Tristano RI;Kataria L;Gadalla SM;Eisenberg DTA;Verhulst S;Drury S
Use of telomere length (TL) as a biomarker for various environmental exposures and diseases has increased in recent years. Various methods have been developed to measure telomere length. Polymerase chain reaction (PCR)-based methods remain wide-spread for population-based studies due to the high-throughput capability. While several studies have evaluated the repeatability and reproducibility of different TL measurement methods, the results have been variable. We conducted a literature review of TL measurement cross-method comparison studies that included a PCR-based method published between January 1, 2002 and May 25, 2020. A total of 25 articles were found that matched the inclusion criteria. Papers were reviewed for quality of methodologic reporting of sample and DNA quality, PCR assay characteristics, sample blinding, and analytic approaches to determine final TL. Overall, methodologic reporting was low as assessed by two different reporting guidelines for qPCR-based TL measurement. There was a wide range in the reported correlation between methods (as assessed by Pearson’s r) and few studies utilized the recommended intra-class correlation coefficient (ICC) for assessment of assay repeatability and methodologic comparisons. The sample size for nearly all studies was less than 100, raising concerns about statistical power. Overall, this review found that the current literature on the relation between TL measurement methods is lacking in validity and scientific rigor. In light of these findings, we present reporting guidelines for PCR-based TL measurement methods and results of analyses of the effect of assay repeatability (ICC) on statistical power of cross-sectional and longitudinal studies. Additional cross-laboratory studies with rigorous methodologic and statistical reporting, adequate sample size, and blinding are essential to accurately determine assay repeatability and replicability as well as the relation between TL measurement methods.
登录
查看更多内容
影响因子:
4.6
作者:
Farmery JHR;Smith ML;NIHR BioResource - Rare Diseases;Lynch AG
通讯作者:
Lynch AG
影响因子:
14.9
作者:
Cawthon RM
通讯作者:
Cawthon RM
DOI:
10.1016/j.mrfmmm.2011.04.003
发表时间:
2012-02-01
影响因子:
2.3
作者:
Aubert, Geraldine;Hills, Mark;Lansdorp, Peter M.
通讯作者:
Lansdorp, Peter M.
影响因子:
20.1
作者:
Benetos A;Toupance S;Gautier S;Labat C;Kimura M;Rossi PM;Settembre N;Hubert J;Frimat L;Bertrand B;Boufi M;Flecher X;Sadoul N;Eschwege P;Kessler M;Tzanetakou IP;Doulamis IP;Konstantopoulos P;Tzani A;Korou M;Gkogkos A;Perreas K;Menenakos E;Samanidis G;Vasiloglou-Gkanis M;Kark JD;Malikov S;Verhulst S;Aviv A
通讯作者:
Aviv A
DOI:
10.1016/j.neo.2018.02.007
发表时间:
2018-05
期刊:
Neoplasia (New York, N.Y.)
影响因子:
--
作者:
Dahlgren PN;Bishop K;Dey S;Herbert BS;Tanaka H
通讯作者:
Tanaka H