Additive effects of touch-activated polymerization and extended irradiation time on bonding of light-activated adhesives to root canal dentin
Additive effects of touch-activated polymerization and extended irradiation time on bonding of light-activated adhesives to root canal dentin
复制标题
DOI:
10.1016/j.prosdent.2020.11.021
复制
发表时间:
2022-05-01
影响因子:
4.6
通讯作者:
Nakajima, Masatoshi
中科院分区:
文献类型:
--
作者:
Dwiandhany, Wahyuni S.;Abdou, Ahmed;Nakajima, Masatoshi
Statement of problem. The bonding of light-activated adhesives to root canal dentin with an additional touch-polymerization activator has been insufficiently examined. Purpose. The purpose of this in vitro study was to investigate the effect of touch-polymerization activators and extended light-irradiation time on the microtensile bond strength (mTBS) of lightactivated adhesives.Material and methods. Post cavities were prepared in 50 extracted mandibular premolars and bonded using Prime&Bond Universal (PBU); PBU+Self Cure Activator (SCA); Clearfil SE Bond 2 (SEB); SEB+Clearfil DC Activator (DCA); or Clearfil Universal Bond Quick ER (UBQ). After lightirradiation for 10 or 20 seconds, the post cavities were filled with dual-activated resin core materials. Eight beams were prepared per specimen and subjected to the mTBS test. The mTBS data were analyzed by using 3-way ANOVAs with the Bonferroni correction (alpha=.05).Results. The 3-way ANOVAs indicated that the use of touch-polymerization activators (SCA and DCA) significantly increased the mTBS of PBU and SEB in both the coronal (P=.015) and apical (P=.001) regions. The extension of light-irradiation time to 20 seconds significantly improved their mTBS in the apical region (P