A compact positron annihilation lifetime spectrometer
A compact positron annihilation lifetime spectrometer
复制标题
DOI:
10.1088/1674-1137/35/1/021
复制
发表时间:
2011
影响因子:
3.6
通讯作者:
李道武;刘军辉;章志明;王宝义;张天保;魏龙;Dw Li;JH Liu;ZM Zhang;Baoyi Wang;Tb Zhang;L. Wei
中科院分区:
文献类型:
--
作者:
李道武;刘军辉;章志明;王宝义;张天保;魏龙;Dw Li;JH Liu;ZM Zhang;Baoyi Wang;Tb Zhang;L. Wei
Using LYSO scintillator coupled on HAMAMATSU R9800 (a fast photomultiplier) to form the small size gamma-ray detectors, a compact lifetime spectrometer has been built for the positron annihilation experiments. The system time resolution FWHM=193 ps and the coincidence counting rate similar to 8 cps/mu Ci were achieved. A lifetime value of 219 +/- 1 ps of positron annihilation in well annealed Si was tested, which is in agreement with the typical values published in the previous lectures.