Structural validity and internal consistency of a hypothesized factor structure of the Fugl-Meyer Assessment of the upper extremity

Structural validity and internal consistency of a hypothesized factor structure of the Fugl-Meyer Assessment of the upper extremity
复制标题

上肢 Fugl-Meyer 评估的假设因素结构的结构有效性和内部一致性

DOI:
10.1080/10749357.2022.2070361
复制
发表时间:
2022
影响因子:
2.2
通讯作者:
Yuta Tauchi and Makoto Kyougoku and Yuho Okita and Takashi Takebayashi
Yuta Tauchi and Makoto Kyougoku and Yuho Okita and Takashi Takebayashi
中科院分区:
医学3区
文献类型:
--
作者:
乙黒 拓哉;岡本 一志;柴田 淳司;Yuta Tauchi and Makoto Kyougoku and Yuho Okita and Takashi Takebayashi

文献摘要

参考文献

相似文献

研究背景上肢Fugl-Meyer评定量表(FMA-UE)的心理测量学特性已被许多研究所证实。虽然存在几个修改版本的FMA-UE形式,其结构效度尚未完全建立。ObjectivesTo assess the structural validity and internal consistency of the original,short,and hypothesized FMA-UE forms.MethodsIn this cross-sectional,multicenter,observational study,the factor structure was assessed using confirmative factor analysis(CFA)to evaluate the adequate model of each hypothesized FMA-UE form(原始、30项、27项和6项表格)。每个FMA-UE形式和分量表的内部一致性进行了评估,使用Cronbach的α因子结构evaluation.ResultsWe招募了363例首次发作中风(中位年龄= 70.0,中位数天= 75.0)。原始模型的结果没有用验证性因素分析进行估计。在所有FMA-UE表格中,30项表格缺少三个反射项(4因素,30项目模型)和27项目模型缺少3个反射和3个协调项目(3因素27项目二阶模型);这些形式证明了适当的模型适应性(近似均方根误差= 0.056/0.059,比较拟合指数= 0.995/0.996,Tucker-Lewis指数= 0.995/0.995)。6项表显示模型拟合较差。结论30项和27项FMA-UE量表具有良好的因子结构,可用于临床实践。然而,未来的研究应确定的因素结构的6个项目的形式。
BackgroundMany studies have confirmed the psychometric properties of Fugl–Meyer Assessment of the upper extremity (FMA-UE). Although several modified versions of the FMA-UE form exist, their structural validity has not been fully established.ObjectivesTo assess the structural validity and internal consistency of the original, short, and hypothesized FMA-UE forms.MethodsIn this cross-sectional, multicenter, observational study, the factor structure was assessed using confirmatory factor analysis (CFA) to evaluate the adequate model of each hypothetical FMA-UE form (original, 30-item, 27-item, and 6-item forms). The internal consistency of each FMA-UE form and subscale was assessed using Cronbach’s alpha after factor structure evaluation.ResultsWe recruited 363 patients with first-episode stroke (median age = 70.0, median days = 75.0). The results of the original form models were not estimated by CFA. Of all FMA-UE forms, the 30-item form lacked three reflex items (4-factor, 30-item model) and the 27-item form lacked three reflex and three coordination items (3-factor, 27-item, second-order model); these forms demonstrated an adequate model fitness (root mean square error of approximation = 0.056/0.059, comparative fit index = 0.995/0.996, Tucker–Lewis index = 0.995/0.995). The 6-item form demonstrated a poor model fit. All FMA-UE forms and subscales showed a high internal consistency (Cronbach’s alpha>0.91).ConclusionsBoth 30- and 27-item FMA-UE forms showed a good factor structure; therefore, these forms are eligible for use in clinical practice. However, future studies should define the factor structure of the 6-item form.
初始屈肌协同模式评分对接受辅助机器人康复治疗的中风患者上肢功能的影响:一项随机临床试验
DOI: 10.1080/10749357.2020.1738660
发表时间: 2020
影响因子: 2.2
作者:
Takashi Takebayashi;Kayoko Takahashi;K. Domen;K. Hachisuka
通讯作者: K. Hachisuka
DOI: --
发表时间: 2021
影响因子: 2.2
作者:
Yuta Tauchi;M. Kyougoku;Kayoko Takahashi;Yuho Okita;Takashi Takebayashi
通讯作者: Takashi Takebayashi
DOI: 10.1016/j.apmr.2016.06.023
发表时间: 2017-03
影响因子: 4.3
作者:
Woytowicz EJ;Rietschel JC;Goodman RN;Conroy SS;Sorkin JD;Whitall J;McCombe Waller S
通讯作者: McCombe Waller S
DOI: 10.2522/ptj.20080285
发表时间: 2009-08-01
期刊: PHYSICAL THERAPY
影响因子: 3.2
作者:
Lin, Jau-Hong;Hsu, Miao-Ju;Hsieh, Ching-Lin
通讯作者: Hsieh, Ching-Lin
偏瘫上肢的功能测试:具有理论意义的 Rasch 分析。
DOI: 10.1016/j.apmr.2017.03.021
发表时间: 2017
影响因子: 4.3
作者:
Rowe,VeronicaT;Winstein,CaroleeJ;Wolf,StevenL;Woodbury,MichelleL
通讯作者: Woodbury,MichelleL