Triggering in trigatron spark gaps: A fundamental study

Triggering in trigatron spark gaps: A fundamental study
复制标题

DOI:
10.1063/1.344001
复制
发表时间:
1989-11
影响因子:
3.2
通讯作者:
Paul F. Williams;F. Peterkin
Paul F. Williams;F. Peterkin
中科院分区:
物理与天体物理3区
文献类型:
--
作者:
Paul F. Williams;F. Peterkin

文献摘要

被引文献

相似文献

The trigatron has been in widespread use as a demand‐triggered, high‐voltage switch for more than 40 years. In spite of the popularity and maturity of the technology, there persists an uncertainty over the basic physical mechanism(s) responsible for triggering breakdown in the devices. We present the results of an empirical study of trigatrons that directly demonstrates that breakdown is initiated by a streamer launched from the trigger pin, independent of the trigger spark. We compare our results with those of previous workers, and discuss the generality of our conclusions.