Analysis of Cs2LiYCl6:Ce3+ (CLYC) waveforms as read out by solid state photomultipliers
Analysis of Cs2LiYCl6:Ce3+ (CLYC) waveforms as read out by solid state photomultipliers
复制标题
固态光电倍增管读出的 Cs2LiYCl6:Ce3 (CLYC) 波形分析
DOI:
10.1109/nssmic.2012.6551123
复制
发表时间:
2012
期刊:
影响因子:
--
通讯作者:
Perry
中科院分区:
文献类型:
--
作者:
B. Budden;A. Couture;L. Stonehill;Alexei;Klimenko;J. R. Terry;John;Perry
Cs2LiYCI6:Ce3+ (CLYC) is a new inorganic scintillator that has recently garnered attention for its ability to detect and discriminate between gammas and thermal neutrons. While scintilla tors are typically coupled to traditional photomultiplier tubes for data acquisition, this setup may not be feasible in all applications. Solid state photomultipliers offer potential advantages including smaller size, added robustness, no high voltage requirement, and imperviousness to magnetic fields. We investigate the waveform structure of CLYC emission when coupled to a SensL silicon photomultiplier and a Hamamatsu multi-pixel photon counter. We report on the ability to provide pulse-shape discrimination for gamma and thermal neutron separation.