Analysis of residual gas by high-resolution mass spectrometry during helium glow discharge cleaning in JT-60U
Analysis of residual gas by high-resolution mass spectrometry during helium glow discharge cleaning in JT-60U
复制标题
DOI:
10.1016/j.fusengdes.2009.02.001
复制
发表时间:
2009-06
影响因子:
5.2
通讯作者:
Takao Hayashi;A. Kaminaga;T. Arai;M. Sato
中科院分区:
文献类型:
--
作者:
Takao Hayashi;A. Kaminaga;T. Arai;M. Sato
The residual gas analysis has been conducted by high-resolution mass spectrometry in JT-60U in order to investigate the effect of helium glow discharge cleaning (He-GDC). The residual gas analyzer was able to distinguish between D2and He peaks during He-GDC. Since the He-GDC started, the partial pressure of D2gas increases with time and reached its highest pressure (3.8×10−4Pa), which was about ten times larger than that before He-GDC. The total amount of D2, which was released during the He-GDC (7h), was evaluated as 4.4Pam3. The pressure of D2after He-GDC was significantly lower than before He-GDC, which indicates that the He-GDC is effective to remove the deuterium from plasma facing components.