Treatment planning of intracranial targets on MRI derived substitute CT data
Treatment planning of intracranial targets on MRI derived substitute CT data
复制标题
DOI:
10.1016/j.radonc.2013.04.028
复制
发表时间:
2013-07-01
影响因子:
5.7
通讯作者:
Nyholm, Tufve
中科院分区:
文献类型:
--
作者:
Jonsson, Joakim H.;Johansson, Adam;Nyholm, Tufve
Background: The use of magnetic resonance imaging (MRI) as a complement to computed tomography (CT) in the target definition procedure for radiotherapy is increasing. To eliminate systematic uncertainties due to image registration, a workflow based entirely on MRI may be preferable. In the present pilot study, we investigate dose calculation accuracy for automatically generated substitute CT (s-CT) images of the head based on MRI. We also produce digitally reconstructed radiographs (DRRs) from s-CT data to evaluate the feasibility of patient positioning based on MR images.Methods and materials: Five patients were included in the study. The dose calculation was performed on CT, s-CT, s-CT data without inhomogeneity correction and bulk density assigned MRI images. Evaluation of the results was performed using point dose and dose volume histogram (DVH) comparisons, and gamma index evaluation.Results: The results demonstrate that the s-CT images improve the dose calculation accuracy compared to the method of non-inhomogeneity corrected dose calculations (mean improvement 2.0% points) and that it performs almost identically to the method of bulk density assignment. The s-CT based DRRs appear to be adequate for patient positioning of intra-cranial targets, although further investigation is needed on this subject.Conclusion: The s-CT method is very fast and yields data that can be used for treatment planning without sacrificing accuracy. (C) 2013 Elsevier Ireland Ltd. All rights reserved.