An 81-year-old man had a mass in the left atrium (LA) that was detected by transthoracic echocardiography at another hospital. To evaluate the characteristics of the mass, ECG-gated enhanced multislice computed tomography (CT) (Aquilion, Toshiba) was performed with a 1-mm slice thickness and helical pitch of 1.0. After intravenous injection of 100 mL of iodinated contrast material (30%), CT scanning was performed with retrospective ECG-gated reconstruction. After acquisition, volume data were extracted from end-diastole, and volume-rendering images were made on a workstation …