The rotate-plus-shift C-arm trajectory. Part II. Exact reconstruction from less than 180° rotation.
The rotate-plus-shift C-arm trajectory. Part II. Exact reconstruction from less than 180° rotation.
复制标题
旋转加移位 C 形臂轨迹第二部分 小于 180° 旋转的精确重建
DOI:
10.1118/1.4944786
复制
发表时间:
2016
期刊:
影响因子:
3.8
通讯作者:
M. Kachelrieß
中科院分区:
文献类型:
--
作者:
J. Kuntz;L. Ritschl;M. Knaup;M. Kachelrieß
PurposeCT reconstruction requires an angular coverage of 180° or more for each point within the field of measurement. Thus, common trajectories use a 180° plus fan angle rotation. This is sometimes combined with a translation of the rotational isocenter in order to achieve circular trajectories with an isocenter different from the mechanical rotation center or elliptical trajectories. Rays measured redundantly are appropriately weighted. In case of an angular coverage smaller than 180°, the reconstructed images suffer from limited angle artifacts. In mechanical constructions with a rotation range limited to less than 180° plus fan angle, the angular coverage can be extended by adding one or two shifts to the rotational motion. If the missing angle is less than the fan angle, the shifts can completely compensate for the limited rotational capabilities.MethodsThe authors give weight functions that can be viewed as generalized Parker weights, which can be applied to the raw data before image reconstruction. Raw data of Forbild phantoms using the rotate‐plus‐shift trajectory are simulated with the geometry of a typical mobile flat detector‐based C‐arm system. Filtered backprojection (FBP) reconstructions using the new redundancy weight are performed and compared to FBP reconstructions of limited angle scans as well as short‐scan reference trajectories using Parker weight.ResultsThe new weighting method is exact in 2D, and for 3D Feldkamp‐type reconstructions, it is exact in the mid‐plane. The proposed weight shows a mathematically exact match with Parker weight for conventional short‐scan trajectories. Reconstructions of rotate‐plus‐shift trajectories using the new weight do not suffer from limited angle artifacts, whereas scans limited to less than 180° without shift show prominent artifacts. Image noise in rotate‐plus‐shift scans is comparable to that of corresponding short scans.ConclusionsThe new weight function enables the straightforward reconstruction using filtered backprojection of data acquired with the rotate‐plus‐shift C‐arm trajectory and a large variety of other advanced trajectories.
DOI:
--
发表时间:
2014
期刊:
影响因子:
--
作者:
Yan Xia;F. Dennerlein;S. Bauer;M. Berger;J. Hornegger;A. Maier
通讯作者:
A. Maier
影响因子:
3.8
作者:
Ritschl, Ludwig;Kuntz, Jan;Kachelriess, Marc
通讯作者:
Kachelriess, Marc
DOI:
10.1109/nssmic.2013.6829341
发表时间:
2013
期刊:
2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)
影响因子:
--
作者:
Y. Xia;M. Berger;C. Riess;J. Hornegger;A. Maier
通讯作者:
A. Maier