The effect of louver blinds on the wind-driven cross ventilation of multi-storey buildings

The effect of louver blinds on the wind-driven cross ventilation of multi-storey buildings
复制标题

DOI:
10.1016/j.jobe.2022.104614
复制
发表时间:
2022-05-21
影响因子:
6.4
通讯作者:
Zheng, Jianwen
Zheng, Jianwen
中科院分区:
工程技术2区
文献类型:
--
作者:
Jiang, Fujian;Tao, Shiwen;Zheng, Jianwen

文献摘要

被引文献

相似文献

Louver blinds is widely used to control indoor solar heat gain at buildings' openings. However, natural ventilation can also be affected by these devices. This study has conducted a CFD investigation on the cross ventilation in a multi-storey building with louver blinds. Taking DFR and air age as the evaluation indicators, the ventilation performance of rooms with different louver angles and wind directions are surveyed. It is found that fully-opened slats may improve the indoor air quality due to its flow fairing, while the larger louver angle can result in greater blocking effect for cross ventilation. Meanwhile, it is shown that windward louvers have a greater impact on ventilation potential than leeward louvers. To provide references for ventilation analysis in louvered rooms, correlations are proposed to describe the promoting or restraining effect of louvers on indoor cross-flow. This research contributes to the integrated design of building's louver blinds.