Effect of axial magnetic fields on electrical characteristics of low-pressure wire discharge
Effect of axial magnetic fields on electrical characteristics of low-pressure wire discharge
复制标题
轴向磁场对低压线放电电特性的影响
DOI:
10.1143/jjap.33.4243
复制
发表时间:
1994
影响因子:
1.5
通讯作者:
T. Tamagawa
中科院分区:
文献类型:
--
作者:
H. Urai;E. Hotta;M. Maeyama;H. Yasui;T. Tamagawa
In order to reveal the potential of wire discharge as a high-density-plasma source, electrical characteristics of a wire discharge plasma were investigated, in particular, taking note of the effect of axial magnetic fields. The dc breakdown voltage and the delay time of a pulse discharge were measured in the presence of an axial magnetic field. When a single-wire anode is adopted, the effect of the magnetic field is very small. On the contrary, in the case of adopting two parallel anode wires, the axial magnetic field affects the discharge properties considerably.