CFRP Shear Strengthening of Reinforced-Concrete T-Beams with Corroded Shear Links
CFRP Shear Strengthening of Reinforced-Concrete T-Beams with Corroded Shear Links
复制标题
DOI:
10.1061/(asce)cc.1943-5614.0000548
复制
发表时间:
2015-10
影响因子:
4.6
通讯作者:
Shunde Qin;S. Dirar;Jian Yang;A. Chan;M. Elshafie
中科院分区:
文献类型:
--
作者:
Shunde Qin;S. Dirar;Jian Yang;A. Chan;M. Elshafie
AbstractThis paper investigates the structural behavior of uncorroded as well as corroded RC T-beams strengthened in shear with either externally bonded (EB) carbon fiber–reinforced polymer (CFRP) sheets or embedded CFRP rods. Nine tests were carried out on RC T-beams having an effective depth of 295 mm and a shear span to effective depth ratio of 3.05. The investigated parameters are the shear link corrosion level (uncorroded, 7% corroded, or 12% corroded) and type of CFRP strengthening system (EB CFRP sheets or embedded CFRP rods). The unstrengthened beams with shear link corrosion levels of 7 and 12% had shear strengths that were 11 and 14%, respectively, less than the shear strength of the uncorroded unstrengthened beam. Both the embedded CFRP rods and EB CFRP sheets were effective in enhancing the shear strength of tested beams but the effectiveness of both strengthening systems decreased with increasing shear link corrosion level. The shear strength enhancement provided by the embedded CFRP rods and...