WHOLE BODY NONRIGID CT-PET REGISTRATION USING WEIGHTED DEMONS.
WHOLE BODY NONRIGID CT-PET REGISTRATION USING WEIGHTED DEMONS.
复制标题
使用加权恶魔进行全身非刚性 CT-PET 配准。
DOI:
10.1109/isbi.2011.5872622
复制
发表时间:
2011
期刊:
影响因子:
--
通讯作者:
Papademetris,X
中科院分区:
文献类型:
--
作者:
Suh,JW;Kwon,Oh-K;Scheinost,D;Sinusas,AJ;Cline,GaryW;Papademetris,X
We present a new registration method for whole-body rat computed tomography (CT) image and positron emission tomography (PET) images using a weighted demons algorithm. The CT and PET images are acquired in separate scanners at different times and the inherent differences in the imaging protocols produced significant nonrigid changes between the two acquisitions in addition to heterogeneous image characteristics. In this situation, we utilized both the transmission-PET and the emission-PET images in the deformable registration process emphasizing particular regions of the moving transmission-PET image using the emission-PET image. We validated our results with nine rat image sets using M-Hausdorff distance similarity measure. We demonstrate improved performance compared to standard methods such as Demons and normalized mutual information-based non-rigid FFD registration.