Studies of proximity focusing RICH with an aerogel radiator using flat-panel multi-anode PMTs (Hamamatsu H8500)
Studies of proximity focusing RICH with an aerogel radiator using flat-panel multi-anode PMTs (Hamamatsu H8500)
复制标题
DOI:
10.1016/j.nima.2003.11.384
复制
发表时间:
2003-09
影响因子:
1.4
通讯作者:
T. Matsumoto;S. Korpar;I. Adachi;S. Fratina;T. Iijima;R. Ishibashi;H. Kawai;P. Križan;S. Ogawa;R. Pestotnik;S. Saitoh;T. Seki;T. Sumiyoshi;K. Suzuki;T. Tabata;Y. Uchida;Y. University;J. S. Institute;Ljubljana;Kek;Tsukuba;Nagoya University;C. University;T. University
中科院分区:
文献类型:
--
作者:
T. Matsumoto;S. Korpar;I. Adachi;S. Fratina;T. Iijima;R. Ishibashi;H. Kawai;P. Križan;S. Ogawa;R. Pestotnik;S. Saitoh;T. Seki;T. Sumiyoshi;K. Suzuki;T. Tabata;Y. Uchida;Y. University;J. S. Institute;Ljubljana;Kek;Tsukuba;Nagoya University;C. University;T. University
A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for upgrading the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4×4 array of 64-channel flat-panel multi-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission length at a high refractive index (n=1.05). Multi-channel PMTs are read-out with analog memory chips. The detector was tested at the KEK-PS π2 beam line in November, 2002. To evaluate systematically the performance of the detector, tests were carried out with various aerogel samples using pion beams with momenta between 0.5 and 4 GeV /c . The typical angular resolution was around 14 mrad , and the average number of detected photoelectrons was around 6. We expect that pions and kaons can be separated at a 4σ level at 4 GeV /c .