Development of quality control system for digital mammographic x-ray units to aim reduction of patient dose
Development of quality control system for digital mammographic x-ray units to aim reduction of patient dose
批准号:
17590452
负责人:
MATSUMOTO Masato
金额:
$1.98万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2005
资助国家:
日本
项目状态:
已结题
起止时间:
2005 至 2006
中文摘要
点击翻译按钮获取中文摘要
英文摘要
The analysis of x-ray spectra is important for quality assurance (QA) and quality control (QC) of radiographic systems. The aim of this study is to measure the digital mammographic x-ray spectra under clinical conditions using a high-resolution Schottky, CdTe detector. Under clinical conditions, the direct measurement of a mammographic spectrum is difficult because of the high photon fluence rates that cause significant detector photon pile-up. An alternative way of measuring the output spectra from a tube is first to measure the 90-degree Compton scattered photons from a given sample. With this set-up detector pile-up is not a problem. From the scattered spectrum one can then use an energy correction and the Klein-Nishina function to reconstruct the actual spectrum incident upon the scattering sample. The verification of whether our spectra measured by the Compton method are accurate was accomplished by comparing exposure rates calculated from the reconstructed spectra to those measur … More ed with an ionization chamber. We used aluminum (Al) filtration ranging in thickness from 0 to 0.8 mm. The difference rates to the dosimeter of the half-value layers (HVLs) obtained for a 27 kV beam were 17.5 % for carbon scatterer and 16.5 % for acrylic resin scatterer. For a 32 kV beam we obtained 12.8 % and 11.4 %. The small differences in HVLs obtained by both techniques suggest that Compton scatter spectroscopy with a high-resolution Schottky CdTe detector is suitable for measuring the digital mammographic x-ray spectra and useful for QA and QC of clinical digital mammographic x-ray equipment.Evaluation standard of phantom images in mammography guideline (second edition) published on March, 2004 including film outcome of digital images was indicated and evaluation of physical imaging properties (digital characteristic curve, modulation transfer function, noise power (Wiener) spectrum, detective quantum efficiency, detectorbility of CDMAM phantom) of digital mammography was explained. Less
期刊论文(25)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
Measurement of position dependence of spectral distribution in primary x-ray beam of CT system using Compton spectroscopy
使用康普顿光谱测量 CT 系统主 X 射线束中光谱分布的位置依赖性
DOI:
--
发表时间:
2005
期刊:
Proceeding of the 19^<th> Workshop on Radiation Detectors and Their Uses 2005・12
影响因子:
--
作者:
[Masao Matsumoto, Koji Maeda]
通讯作者:
Koji Maeda
Spectral measurement of diagnostic x-ray unit
诊断 X 射线装置的光谱测量
DOI:
--
发表时间:
2005
期刊:
Japanese Journal of Medical Physics 25・Sup.4
影响因子:
--
作者:
[Dodds, A.W., KIBI Noboru, M.Matsumoto]
通讯作者:
M.Matsumoto
Effect of scatterer on mammographic x-ray spectra measured by Compton spectroscopy
散射体对康普顿光谱测量的乳腺 X 射线光谱的影响
DOI:
--
发表时间:
2006
期刊:
Radiation Detectors and Their Uses, KEK Proceedings 2006-7
影响因子:
--
作者:
[Masao Matsumoto, Kentaro Onishi, Chikako Tanaka]
通讯作者:
Chikako Tanaka
Novel display technique for reference images for visibility of temporal change on radiography -Color digital summation radiography-
用于参考图像的新颖显示技术,可在放射线照相上显示时间变化 -彩色数字求和放射线照相 -
DOI:
--
发表时间:
2006
期刊:
Radiation Medicine 24・1
影响因子:
--
作者:
[Ogata Y, Naito H, Tomiyama N, Hamada S, Tsubamoto M, Inoue A, Murai S, Sumikawa H, Ueguchi T, Matsumoto M, Tamura S, Nishinosono H, Nakamura H, Johkoh T]
通讯作者:
Johkoh T
Evaluation of physical imaging properties of Digital mammography
数字乳腺X线摄影物理成像特性的评估
DOI:
--
发表时间:
2006
期刊:
Medical Imaging and Information Sciences 23・2
影响因子:
--
作者:
[Endo, Y., 佐藤恵子, Kuraya M, M.Matsumoto]
通讯作者:
M.Matsumoto
共 20 条