Development of an anastomotic device for distal anastomosis to achieve marked improvement of total arch replacement
Development of an anastomotic device for distal anastomosis to achieve marked improvement of total arch replacement
批准号:
16500312
负责人:
IMAMAKI Mizuho
金额:
$1.22万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2004
资助国家:
日本
项目状态:
已结题
起止时间:
2004 至 2005
中文摘要
点击翻译按钮获取中文摘要
英文摘要
[Purpose]To achieve marked improvement of graft replacement for aortic arch aneurysm, distal anastomosis must be performed without hemorrhage and in a short time. We developed an anastomotic device for distal anastomosis and conducted a basic experiment to confirm its efficacy. [Methods]The anastomotic device has a mechanism to facilitate mattress sutures. Bovine thoracic aorta and grafts (20 mm and 26 mm in outer diameter) were used. EPTFE felts were used for the outer side of the aorta. The suture needle was 9.0 mm in length and suture threads with straight stitches were used. [Results]1.Thickness of the aortic wall and the certainty of handing over of the needle : Although the needle was handed over accurately by the anastomotic device up to aortic wall thickness of 4.6 mm, difficulties were encountered in some cases with wall thicknesses of 4.8 mm or more. 2.Distance between adjacent mattress sutures : In the case of 2.0 mm, a space between adjacent mattress sutures was found and leakage from the anastomosis site was found in water infusion test. In the cases of 1.0 mm and of 1.0 mm overlap, no penetrating space was found between adjacent mattress sutures. 3.Inter-needle distance of the anastomotic device : With the inter-needle distance of 5.0 mm, there was no problem in the mechanism of needle handing over and no spaces were found between the mattress sutures. With an inter-needle distance of 7.5 mm, the needle bent and the handing over mechanism was disturbed in some cases due to the aortic curvature face and the hardness of the tissues. When there was no overlap of adjacent mattress sutures, spaces were produced between the mattress sutures themselves. [Conclusions]With an inter-needle distance of 5.0 mm and adjacent mattress suture interval of 1.0 mm, the development of anastomotic device in the present study suggested that a clinically useful anastomotic device could be made in the future.
期刊论文(9)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
遠位弓部大動脈瘤に対する手術術式の工夫
远端主动脉弓瘤手术技术的改进
DOI:
--
发表时间:
2004
期刊:
日本血管外科学会雑誌 13・2
影响因子:
--
作者:
[Kazuo Nakazawa, Ryo Haraguchi, Takenori Yao, Hiroshi Nagata, Yoshihisa Sugigmoto, Takeo Igarashi et al., 今牧瑞浦ほか]
通讯作者:
今牧瑞浦ほか
胸部大動脈瘤手術の低侵襲化を目的とした大動脈・人工血管吻合器の考案・作製と実験的検討
用于微创胸主动脉瘤手术的主动脉/人工血管吻合装置的设计、制造和实验研究
DOI:
--
发表时间:
2006
期刊:
日本外科学会 107・2
影响因子:
--
作者:
[中沢一雄, 原口亮, 芦原貴司, 八尾武憲, 難波経豊, 池田隆徳, 鈴木亨, 他, 今牧端蒲]
通讯作者:
今牧端蒲
Is it safe to initiate selective cerebral perfusion?
启动选择性脑灌注安全吗?
DOI:
--
发表时间:
2005
期刊:
J Card Surg
影响因子:
--
作者:
[中沢一雄, 原口亮, 芦原貴司, 八尾武憲, 難波経豊, 池田隆徳, 鈴木亨, 他, 今牧端蒲, 今牧瑞浦, Imamaki et al.]
通讯作者:
Imamaki et al.
Development of an anastomotic device for distal anastomosis to achieve marked improvement of total arch replacement
开发远端吻合吻合器,显着改善全牙弓置换术
DOI:
--
发表时间:
2006
期刊:
Journal of Japan Surgical Society Vol.107-2
影响因子:
--
作者:
[中沢一雄, 原口亮, 八尾武憲, 永田啓, 杉本喜久, 五十嵐健夫 他, Mizuho Imamaki]
通讯作者:
Mizuho Imamaki
DOI:
--
发表时间:
2004
期刊:
J Jpn Coll Angiol 44・12
影响因子:
--
作者:
[Yuki Mori, Takeo Igarashi, Tatsuo Yoshida, Tsuneyoshi Ohkawa, Ryo Haraguchi, Kazuo Nakazawa, 田渕圭章ら, Imamaki et al.]
通讯作者:
Imamaki et al.
海外基金