Development of the dose distribution measurement equipment for Gafchromic film in radiotherapy

Development of the dose distribution measurement equipment for Gafchromic film in radiotherapy
放射治疗中Gafchromic胶片剂量分布测量设备的研制
批准号:
16591205
负责人:
AZUMA Yoshiharu
金额:
$1.79万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2004
资助国家:
日本
项目状态:
已结题
起止时间:
2004 至 2005

项目摘要

项目成果

AZUMA Yoshiharu的其他基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
The purpose of our research is the development of inexpensive and high-speed measurement equipment for the improvement of dose distribution measurement accuracy of Gafchromic film in high energy x-rays. First, the measurement light source of the transmission unit of a general-purpose flat-bed scanner, ES-2200 (EPSON) was converted into the wavelength of 670 nm for Gafchromic film MD-55 and HS in 2005. Moreover, since EBT model was also put on the market in addition to Gafchromic film MD-55 and HS, the transmission unit of measurement wavelength 630 nm is ordered. Performance evaluation of the scanner to Gafchromic film MD-55, HS and EBT was performed. The outline of the result is summarized to below.1. Match to the measurement light source wavelength of the scanner to Gafchromic filmsGafchromic film MD-55 and HS have the absorption spectrum with a maximum absorption band centered at 670 nm and Gafchromic film EBT has the absorption spectrum with a maximum absorption band centered at 636 run. For two wavelengths, the form that consists of one body of a general-purpose flat-bed scanner and two exchange transmission units with different measurement LED light source was chosen. Thereby, the inexpensive scanner of a multiple use way has been realized.2. Improvement in measurement sensitivityFrom having adjusted to the measurement light source with the maximum absorption wavelength to each Gafchromic film, the density measurement system of high sensitivity of 1.5-1.8 was able to be completed as compared with use of the conventional general-purpose flat-bed scanner. Furthermore, when performing the measure against a noise well, it became possible to raise measurement accuracy.
期刊论文(2)
专著(0)
科研奖励(0)
会议论文
DOI: --
发表时间: 2004
期刊: 日本放射線技術学会雑誌 60・11
影响因子: --
作者: [Yamakado K, Takeda K, 他., 青山英樹]
通讯作者: 青山英樹
Study on the dose distribution measurement precision in the radiotherapy using GAFchromic film
  • 批准号:
    14570859
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $1.22万
  • 财政年份:
    2002
  • 负责人:
    AZUMA Yoshiharu
  • 依托单位: