课题基金 / 基金详情

Optimum display of the digital intraoral imaging system by quantitative evaluation on image quality

Optimum display of the digital intraoral imaging system by quantitative evaluation on image quality
通过图像质量的定量评价优化数字口腔内成像系统的显示
批准号:
16591888
负责人:
YOSHIURA Kazunori
金额:
$1.92万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2004
资助国家:
日本
项目状态:
已结题
起止时间:
2004 至 2005

项目摘要

项目成果

YOSHIURA Kazunori的其他基金

相关文献

中文摘要
翻译
数字系统广泛应用于医学成像,这一趋势也出现在普通牙科医生中。然而,没有得到共识的最佳显示的数字图像和信息的数字图像没有完全用于诊断和治疗planning.In这项研究中,低对比度的可检测性的数字系统进行了比较,在电影中使用专门开发的图像质量幻影进行定量评估。然后用相同的系统和相同的观察者评价离体牙邻面龋的诊断准确性,回归分析显示低对比度检测能力与诊断准确性之间存在高度相关性。数字系统和胶片的诊断准确性之间没有统计学显著差异。然而,曝光对诊断准确性或低对比度可检测性的影响在数字系统中比在胶片中更大。这种影响在有自动曝光补偿的数字系统中比没有自动曝光补偿的数字系统中要小。进一步的研究表明,数字系统的图像对比度与胶片的图像对比度完全不同。数字系统在低曝光下的图像对比度远不如胶片。我们开发的图像显示算法,以提高在低曝光的对比度。结果表明,处理后的图像整体对比度优于原始图像,与胶片图像对比度相近,该图像显示算法可普遍适用于所有数字化口内成像系统。
英文摘要
Digital system is widely used in medical imaging and this trend is found in general dental practitioners, too. However, no consensus was obtained about the optimum display of the digital image and information in the digital images are not fully used for diagnosis and treatment planning.In this study, low contrast detectability in the digital systems was compared with that in the film using specially developed image quality phantom for quantitative evaluation. Then diagnostic accuracy for proximal caries of the extracted teeth was evaluated using the same systems and the same observers.Regression analysis showed high correlation between low contrast detectability and diagnostic accuracy. There was no statistically significant difference between diagnostic accuracy of the digital systems and that of the film. Effect of exposure on diagnostic accuracy or low contrast detectability, however, was larger in the digital systems than in the film. This effect was smaller in the digital system with automatic exposure compensation than in that without it.Further investigation clarified that image contrast of the digital system was completely different from that of the film. Image contrast of the digital system in low exposure was far inferior to that of the film. We developed the image display algorithm to improve contrast in low exposure. The result showed that overall image contrast of the processed image was better than that of the original and it was similar to that of the film.This image display algorithm may have general applicability to all digital intraoral imaging systems.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Development of a new method for evaluation CBCT images
  • 批准号:
    21592388
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $3.0万
  • 财政年份:
    2009
  • 负责人:
    YOSHIURA Kazunori
  • 依托单位:
Attempt for kinetic analysis in head and neck region using enhanced MRI
  • 批准号:
    18592063
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $2.42万
  • 财政年份:
    2006
  • 负责人:
    YOSHIURA Kazunori
  • 依托单位:
Automated quantitative diagnosis system for dental diseases by optimum image processing
  • 批准号:
    14571791
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $1.86万
  • 财政年份:
    2002
  • 负责人:
    YOSHIURA Kazunori
  • 依托单位:
DEVELOPMENT OF GLOBAL STANDARD PHANTOM TO OPTIMIZE DIGITAL
  • 批准号:
    09671923
  • 项目类别:
    Grant-in-Aid for Scientific Research (C)
  • 资助金额:
    $2.18万
  • 财政年份:
    1997
  • 负责人:
    YOSHIURA Kazunori
  • 依托单位: