中文摘要
本研究的目的是开发一种电极可贴附于人体表面的无线能量传输系统。将发射电极连接到日本成年男性的34个组织的人体模型。然后,通过进行电磁分析,我们估计了放置在模型腹部深部(骨骼、肌肉和脂肪)的植入式设备的接收功率。我们发现,最大接收功率为2毫瓦超过40兆赫。该系统可以将电能传输到低功耗的小型植入式医疗设备。
英文摘要
The propose of this study is developing a wireless energy transmission system whose electrodes can be attached to the human body surface. The transmitting electrode was attached to a human model of 34 tissue of a Japanese adult male. Then, by performing electromagnetic analysis, we estimated the receiving power of an implantable device placed in the deep abdominal area (bone, muscle, and fat) of the model. We found the maximum receiving power to be 2 mW over 40 MHz. This system can electric power transmission power to small implantable medical devices of low power consumption.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
体内埋込型小型医療機器のための 容量結合型非接触電力伝送-送受電電極面積と受電電力の関係-
植入体内的小型医疗设备的电容耦合非接触电力传输 - 电力发射/接收电极面积与接收功率之间的关系 -
DOI:
--
发表时间:
2010
期刊:
電気学会リニアドライブ研究会
影响因子:
--
作者:
[種田敦, 柴建次]
通讯作者:
柴建次
高周波電流による体内埋込型医療機器への無線電力伝送-受電電力とSAR,電流密度の解析-
使用高频电流向植入式医疗设备进行无线电力传输 - 分析接收功率、SAR 和电流密度 -
DOI:
--
发表时间:
2010
期刊:
影响因子:
--
作者:
[柴建次, 丸山大海]
通讯作者:
丸山大海
容量結合を利用した体内埋込式小型医療機器用非接触電力伝送-最適な伝送周波数の検討-
利用电容耦合对植入体内的小型医疗设备进行非接触式电力传输 - 最佳传输频率的研究 -
DOI:
--
发表时间:
2009
期刊:
影响因子:
--
作者:
[丸山大海, 平野陽豊, 檜垣直哉, 柴建次]
通讯作者:
柴建次
Energy Transmission for Implantable Medical Devices Using Capacitive Coupling
使用电容耦合的植入式医疗设备的能量传输
DOI:
--
发表时间:
2010
期刊:
影响因子:
--
作者:
[柴建次, 丸山大海, 檜垣直哉]
通讯作者:
檜垣直哉
非接触電力伝送システムおよび電子装置
非接触式电力传输系统和电子设备
DOI:
--
发表时间:
2008
期刊:
影响因子:
--
作者:
[]
通讯作者:
共 12 条
海外基金