NONINVASIVE BLOOD LOSS MONITOR FOR OBSTETRICS
NONINVASIVE BLOOD LOSS MONITOR FOR OBSTETRICS
批准号:
2714150
负责人:
ROBERT G BILLINGS
金额:
$10.0万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
1998
资助国家:
美国
项目状态:
已结题
起止时间:
1998-09-30 至 2000-03-29
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Post partum hemorrhage, a major cause of maternal morbidity and mortality
in childbirth has not been quantitatively assessable due to the lack of
a noninvasive instrument for the measurement of maternal blood loss. A
noninvasive, convenient and inexpensive method is needed to detect and
assess the degree of post partum blood loss so that appropriate
interventions can be applied. Investigations that will lead to the
development a measurement system that will meet this need is proposed
herein. The proposed method uses conventional indicator dilution theory,
substituting the 18O2 stable oxygen isotope with a combination of inert
gases for the more commonly used dyes and radioactive tracers. Using
these tracers, total blood volume, Vb, hemoglobin, Hb, and blood loss,
BL, will be measured. Preliminary experiments in the proposing laboratory
have demonstrated the feasibility of the proposed method and have brought
about the acquisition of most of the special purpose instrumentation that
will be needed. In this study all the proposed measurement techniques
will be conclusively validated and the methods will be refined to meet
the accuracy criteria necessary for clinical utility in obstetrics
practice as well as research. Experiments in dogs will be conducted in
which degrees of blood loss will be imposed by repeated exsanguination
and retransfusion while measurements of Vb, Hb, and BL are made using the
tracer methods. Subsequently human volunteers will be used to validate
these measures within their expected physiologic ranges. BL measurement
sensitivity will be observed in human blood donors. Also these donors
will be evaluated for hemoglobin changes after donation. Finally
demonstration will be made of the ability to apply the method to women
during labor. Hardware and software engineering for the design of a
device will be relegated to Phase II.
PROPOSED COMMERCIAL APPLICATIONS:
Since a non-invasive blood volume monitoring system does not presently
exist, a commercial device incorporating the methods developed in this
program will fill an immediate need in the clinical practice of
obstetrics.. Essentially the same device will fill an important role in
other blood loss monitoring situations including surgery and trauma.