REMOTE PRESSURE MONITORING IN BK DIABETIC AMPUTEES
REMOTE PRESSURE MONITORING IN BK DIABETIC AMPUTEES
批准号:
2655132
负责人:
STEPHEN H. SPRIGLE
金额:
$15.46万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
1994
资助国家:
美国
项目状态:
已结题
起止时间:
1994-02-01 至 2000-01-31
中文摘要
点击翻译按钮获取中文摘要
英文摘要
This study will measure the mechanical loading conditions that proceed
pathological changes in soft tissues of diabetic amputees being fitted
with their first below knee, permanent prosthesis. Our preliminary work
has established a non-invasive method for monitoring skin response to
prolonged loading, using tissue reflectance spectrometry (TRS). We have
extensively characterized the post ischemia responses of spinal cord
injured and multiple sclerosis subjects and will extend in this study the
measurements to diabetic amputees. Our current work has also
demonstrated an effective method for accommodating for the effects of
skin pigmentation on the primary measurement parameters - superficial
skin blood content and oxygenation. These parameters can now be
accurately measured in black subjects and other ethnic groups. The first
two years will concentrate on collecting normative TRS post ischemia
response data on diabetic amputees at sites on the residual limb known
to be at risk. The effect of repetitive vs prolonged loading, and
amplitude of loading will also be contrasted. During this time TRS will
also be used to dynamically characterize the blood content and
oxygenation status of BK amputees who present at our clinic with
localized pain and/or persistent skin redness. The investigators have
also contributed to the development and evaluation of advanced pressure
mapping technology for clinical seating and positioning applications.
In the first two years we will further develop this technology for
measurement of stump-socket interface pressures during everyday use of
the prosthesis. In collaboration with Tekscan Inc., modifications to
existing technology will be made in Years 1 and 3 to permit ambulatory
monitoring of interface pressures. In years 3-5 we will study tissue
response to loading history for over 100 BK diabetic amputees in the
community, during the period immediately after the fitting of the
patient's first permanent prosthesis. Four days after the fitting, the
TRS will be used to evaluate areas of the residual limb that normally
exhibit localized damage, inflammation or pain and the extent of any
adverse responses will be measured. The detailed loading history that
proceeded the tissue response will be extracted from the data collected
during the monitoring period. Parameters to characterize loading history
will include: number of loading repetitions; magnitude and duration of
peak loads; duration of walking sessions; peak pressures during swing
phase and pertinent clinical data.
期刊论文(1)
专著(0)
科研奖励(0)
会议论文
Testing the validity of erythema detection algorithms.
测试红斑检测算法的有效性。
DOI:
--
发表时间:
2001
期刊:
Journal of rehabilitation research and development.
影响因子:
--
作者:
[Riordan,B, Sprigle,S, Linden,M]
通讯作者:
Linden,M
Erythema and deep tissue injury detector
-
批准号:6726409
-
项目类别:
-
资助金额:$48.11万
-
财政年份:2004
-
负责人:STEPHEN H. SPRIGLE
-
依托单位:
REMOTE PRESSURE MONITORING IN BK DIABETIC AMPUTEES
-
批准号:2332273
-
项目类别:
-
资助金额:$16.04万
-
财政年份:1994
-
负责人:STEPHEN H. SPRIGLE
-
依托单位:
REMOTE PRESSURE MONITORING IN BK DIABETIC AMPUTEES
-
批准号:2203943
-
项目类别:
-
资助金额:$15.78万
-
财政年份:1994
-
负责人:STEPHEN H. SPRIGLE
-
依托单位:
海外基金