Insulating Coatings for Implant Devices & Ribbon Cables
植入设备的绝缘涂层
基本信息
- 批准号:6896142
- 负责人:
- 金额:$ 34.56万
- 依托单位:
- 依托单位国家:美国
- 项目类别:
- 财政年份:2000
- 资助国家:美国
- 起止时间:2000-11-01 至 2006-09-29
- 项目状态:已结题
- 来源:
- 关键词:biomaterial compatibilitybiomaterial development /preparationbiomaterial interface interactiondogselectrical impedanceelectrical potentialelectrochemistryelectrodeselectroretinographyelectrostimuluseye fundus photographyhistologyimplantiridiummedical implant sciencemetal oxidenervous system prosthesisoptical tomographyplatinumretinasurface coating
项目摘要
DESCRIPTION (provided by applicant): We propose the development of a novel flexible integrated microelectrode array as active stimulating interface to the neural system in the retina of the human eye. Our approach, in which microelectrode arrays, interconnecting leads and circuitry traces are embedded and integrated on a single flexible polyimide foil and encapsulated with our proprietary materials will overcome the classical separation of substrate and insulation layers, a weak point in many biomedical implant devices. To achieve this goal we will combine our proprietary A-Coat TM encapsulation technology for flex substrates with our proprietary metal-to-flex substrate adhesion technology. This implant device promises to deliver improved long-term performance under stimulating pulsed conditions and excellent long-term biocompatibility.
描述(由申请人提供):我们提出开发一种新型柔性集成微电极阵列,作为人眼视网膜神经系统的主动刺激界面。我们的方法,其中微电极阵列,互连引线和电路迹线嵌入和集成在一个单一的柔性聚酰亚胺箔,并与我们的专有材料封装将克服经典的分离基板和绝缘层,在许多生物医学植入设备的弱点。为了实现这一目标,我们将联合收割机结合我们专有的A-Coat TM封装技术与我们专有的金属-柔性基板粘合技术。该植入器械有望在刺激脉冲条件下提供改善的长期性能和出色的长期生物相容性。
项目成果
期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)
数据更新时间:{{ journalArticles.updateTime }}
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ patent.updateTime }}
Helmut Eckhardt其他文献
Helmut Eckhardt的其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
{{ truncateString('Helmut Eckhardt', 18)}}的其他基金
Hybrid retinal prosthesis utilizing bioadhesives for reversible attachment
利用生物粘合剂进行可逆附着的混合视网膜假体
- 批准号:
7926879 - 财政年份:2010
- 资助金额:
$ 34.56万 - 项目类别:
Novel High Density Interconnects for Flexible Neural Prostheses
用于灵活神经假体的新型高密度互连
- 批准号:
8201021 - 财政年份:2006
- 资助金额:
$ 34.56万 - 项目类别:
Novel High Density Interconnects for Flexible Neural Prostheses
用于灵活神经假体的新型高密度互连
- 批准号:
7109086 - 财政年份:2006
- 资助金额:
$ 34.56万 - 项目类别:
Novel High Density Interconnects for Flexible Neural Prostheses
用于灵活神经假体的新型高密度互连
- 批准号:
8320158 - 财政年份:2006
- 资助金额:
$ 34.56万 - 项目类别:
Insulating Coatings for Implant Devices and Ribbon Cables
植入设备和带状电缆的绝缘涂层
- 批准号:
7485775 - 财政年份:2001
- 资助金额:
$ 34.56万 - 项目类别:
Insulating Coatings for Implant Devices & Ribbon Cables
植入设备的绝缘涂层
- 批准号:
7240126 - 财政年份:2000
- 资助金额:
$ 34.56万 - 项目类别:
Insulating Coatings for Implant Devices and Ribbon Cables
植入设备和带状电缆的绝缘涂层
- 批准号:
7222044 - 财政年份:2000
- 资助金额:
$ 34.56万 - 项目类别:
Insulating Coatings for Implant Devices & Ribbon Cables
植入设备的绝缘涂层
- 批准号:
6736554 - 财政年份:2000
- 资助金额:
$ 34.56万 - 项目类别:
Insulating Coatings for Implant Devices and Ribbon Cables
植入设备和带状电缆的绝缘涂层
- 批准号:
7294310 - 财政年份:2000
- 资助金额:
$ 34.56万 - 项目类别: