课题基金 / 基金详情

项目摘要

项目成果

Paul Arthur Bierden的其他基金

相关文献

中文摘要
翻译
描述(由申请人提供):本提案描述了一项开发适合商用眼科自适应光学的长行程MEMS变形镜的计划。它们将被设计成允许至少90%的人通过放大瞳孔进行衍射受限的视网膜成像。第一阶段研究中展示的静电致动器设计和制造工艺将作为这些mems - dm的基础,这些mems - dm将使用硅片批量生产。根据先前的研究,估计补偿眼睛的像差将需要高达12¿m的波前补偿(在MEMS-DM校正之前补偿焦点和散光)。由于反射使镜面变形在波前增加了一倍,这将需要DM在每个执行器处至少有6¿m的行程。第二个目标将是证明衍射限制视网膜成像的人类受试者的眼睛光学像差,包括超过90%的范围在人群中发现。长行程MEMS可变形镜将与第一阶段展示的光学倍频器相结合,以实现12¿m的有效变形镜运动,对应于24¿m的波前校正,并将集成到经过验证的自适应光学扫描激光检眼镜设计中。添加光学倍频器到系统将允许变形镜纠正低阶(像散)像差。这种大的行程,结合Badal验光计的设计,将消除对每只受试者眼睛使用矫正镜片的需要,并允许前所未有的人体视网膜的体内成像。由于眼像差限制了成像分辨率,研究人员和临床医生一直无法看到人类视网膜的关键特征。拟议项目的成功完成将为比以往任何时候都更好的人类视网膜分辨率成像提供使能组件。图像质量的提高将使临床医生能够检测和诊断糖尿病视网膜病变和黄斑变性,并在药物研究中确定药物的疗效。
英文摘要
DESCRIPTION (provided by applicant): This proposal describes a plan to develop long stroke MEMS deformable mirrors suitable for use in commercial ophthalmic adaptive optics. They will be designed to permit diffraction-limited retinal imaging through dilated pupils in at least 90% of the human population. Electrostatic actuator design and manufacturing processes demonstrated in Phase I research will be used as a foundation for these MEMS-DMs, which will be produced using silicon wafer batch-manufacturing. Based on prior research, it is estimated compensation of aberrations of the eye will require up to 12¿m of wavefront compensation (with focus and astigmatism compensated before MEMS-DM correction). Because mirror deformation is doubled in the wavefront by reflection, this will require a DM with at least 6¿m of stroke at each actuator. A second goal will be to demonstrate diffraction-limited retinal imaging in human subjects possessing optical aberrations of the eye that encompasses more than 90% of the range found in the population. The long-stroke MEMS deformable mirror will be combined with the optical doubler demonstrated in the Phase I effort to achieve an effective deformable mirror motion of 12¿m, corresponding to 24¿m of wavefront correction, and will be integrated into a proven adaptive optics scanning laser ophthalmoscope design. Adding the optical doubler to the system will allow for the deformable mirror to correct for low order (astigmatic) aberrations. This large stroke, combined with a Badal optometer design, will eliminate the need to use corrective lenses for each subject eye and allow unprecedented in vivo imaging of the human retina. Researchers and clinicians have been unable to see critical features in the human retina due to ocular aberrations that limited imaging resolution. A successful completion of the proposed project will provide the enabling component for better resolution imaging of the human retina than ever before. This improvement in image quality will allow clinicians to detect and diagnose diabetic retinopathy and macular degeneration as well as to determine the efficacy of drugs in drug studies.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Long Stroke Wavefront Correctors for Retinal Imaging
  • 批准号:
    7491418
  • 项目类别:
  • 资助金额:
    $22.51万
  • 财政年份:
    2005
  • 负责人:
    Paul Arthur Bierden
  • 依托单位:
Adaptive Optics Retinal Imaging in a Clinical Setting Using Long Stroke Wavefront
  • 批准号:
    8314923
  • 项目类别:
  • 资助金额:
    $76.71万
  • 财政年份:
    2005
  • 负责人:
    Paul Arthur Bierden
  • 依托单位:
Long Stroke Wavefront Correctors for Retinal Imaging
  • 批准号:
    6882129
  • 项目类别:
  • 资助金额:
    $10.0万
  • 财政年份:
    2005
  • 负责人:
    Paul Arthur Bierden
  • 依托单位:
Adaptive Optics Retinal Imaging in a Clinical Setting Using Long Stroke Wavefront
  • 批准号:
    8515418
  • 项目类别:
  • 资助金额:
    $55.03万
  • 财政年份:
    2005
  • 负责人:
    Paul Arthur Bierden
  • 依托单位: