DUAL TUNED HELMHOLTZ COIL FOR BREAST CANCER IMAGING
DUAL TUNED HELMHOLTZ COIL FOR BREAST CANCER IMAGING
批准号:
7955421
负责人:
Anderson Nnewihe
金额:
$1.8万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2009
资助国家:
美国
项目状态:
已结题
起止时间:
2009-06-01 至 2010-05-31
关键词:
BenignBreastBreast Cancer DetectionCancerousClinicalComputer Retrieval of Information on Scientific Projects DatabaseEnhancing LesionFundingGoalsGrantImageInstitutionLawsMagnetic Resonance ImagingMalignant NeoplasmsMammary NeoplasmsMammographyMeasurementMembraneModelingPhysiologic pulsePumpRF coilResearchResearch PersonnelResourcesRoentgen RaysScreening procedureSensitivity and SpecificitySignal TransductionSodiumSourceSpecificitySurfaceTechnologyUnited States National Institutes of Healthcancer imagingimaging modalityimprovedmalignant breast neoplasmtumor
中文摘要
点击翻译按钮获取中文摘要
英文摘要
This subproject is one of many research subprojects utilizing the
resources provided by a Center grant funded by NIH/NCRR. The subproject and
investigator (PI) may have received primary funding from another NIH source,
and thus could be represented in other CRISP entries. The institution listed is
for the Center, which is not necessarily the institution for the investigator.
Clinical breast exams have limited specificity and sensitivity for detecting breast tumors. Even X-ray mammography, which is used for early screening of breast tumors, has limited sensitivity and does not detect approximately25% of breast cancers. Dynamic contrast-enhanced MRI (DCE-MRI) has high sensitivity but low specificity; i.e., both cancerous and benign lesions enhance [2]. Additional imaging modalities such as sodium (23Na) MR have the potential to increase the sensitivity and specificity of breast cancer
detection because 23Na MR can reflect the disruption of the membrane Na-K pump associated with cancer. Moreover, recent advances in gradient hardware and pulse sequences have made 23Na MR feasible for quantitative measurements of sodium concentration.
Preliminary results of multinuclear MRI using a receive-only H surface coil and a transmit/ receive 23Na surface coil show elevated 23Na signal in the tumor. Although the surface coil provides high SNR images, there is significant
B1 inhomogeneity as modeled by Biot-Savart's law. For quantifying 23Na concentration in the breast, we need an RF coil that improves B1 homogeneity
without sacrificing SNR. The goals of this study were to build a dual-tuned Helmholtz coil, to investigate
the difference between a dual-tuned Helmholtz coil and a dual-tuned surface coil in providing high SNR and high quality B1 homogeneity for multinuclear imaging, and to perform preliminary breast imaging using the dual-tuned Helmholtz coil.