Compliant Thoracic Artificial Lungs
Compliant Thoracic Artificial Lungs
批准号:
8011512
负责人:
Keith E Cook
金额:
$35.52万
依托单位国家:
美国
项目类别:
财政年份:
2009
资助国家:
美国
项目状态:
已结题
起止时间:
2009-01-01 至 2012-12-31
关键词:
AcuteAnimal ModelAnimalsBenchmarkingBlood CirculationBlood flowCarbon DioxideCardiac OutputChestChronicChronic lung diseaseCoagulation ProcessDataDevelopmentDevice DesignsDevicesDisease modelDistalEnsureExerciseExtracorporeal Membrane OxygenationFiltrationFunctional disorderGasesGoalsHealthHeartHousingIn VitroInflammationLeft atrial structureLiquid substanceLong-Term EffectsLungLung TransplantationLung diseasesMechanical ventilationMechanicsMetabolicMethodsModelingOrganOutcomeOutputPatientsPerformancePhysiologyPulmonary Artery BranchPulmonary HypertensionPulmonary Vascular ResistancePulmonary artery structurePulsatile FlowPumpResistanceRight Ventricular FunctionRight ventricular structureSheepSimulateStagingStructureSystemTestingTimeTransplant RecipientsTransplantationVentricularWorkartificial lungbasedesignelectric impedanceengineering designhemodynamicsimprovedin vitro testingin vivomeetingsprototyperesearch clinical testingrespiratory
中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): The long-term objectives of this proposal are to develop compliant, thoracic artificial lungs (cTALs) that can be used as a bridge to transplant for patients with end-stage respiratory disease. As a bridge to lung transplantation, a cTAL would allow for more patients to be transplanted and improve outcomes. Blood flow to the cTAL comes from the pulmonary artery (PA), driven by the right ventricle. Blood flow returns to the distal PA or branch of the PA (PA-PA attachment) or the left atrium (PA-LA attachment). These devices are designed to supply a patient's full gas transfer requirements with significantly less coagulation and inflammation than with extracorporeal membrane oxygenation (ECMO). Our group's previous work has led to devices that met these goals in large animals. However, this work also indicates that the fluid mechanical impedance of these devices can cause a significant reduction in cardiac output (CO) when attached in the PA- PA configuration. If not for this reduction in CO, PA-PA attachment would be the ideal means of attaching cTALs, as it allows the natural lung to maintain its normal filtration and metabolic functions. The cause of the reduction in CO is due, in large part, to excessive cTAL impedance. The studies in this proposal are aimed at designing a cTAL with very low impedance such that it can be used in any attachment configuration with little to no reduction in CO. This design should also allow for increases in CO with exercise. Five studies are proposed to meet this goal. (1) The relationship between pulmonary system impedance and CO will be determined using an intact heart, large animal model. The developed relationship will be used to set impedance benchmarks for the design of an improved cTAL that causes little to no reduction in CO during PA-PA attachment. (2) Fluid structure interaction (FSI) modeling will be used to design a cTAL that meets the impedance benchmarks. Preliminary FSI and in-vitro data indicates that cTAL impedance can be reduced to at least 33-50% of current thoracic artificial lungs. This should result in large improvements in CO during cTAL use. (3) The selected design will be tested in-vitro under pulsatile flow to confirm hemodynamic performance. (4) The cTAL will be tested in-vivo to determine short term (< 8 hrs) gas exchange and hemodynamic performance in the PA-PA and PA-LA configurations at normal and elevated CO. Lastly, (5) the cTAL will be tested in-vivo over 14 days to assess device performance and animal physiology. All animal studies will utilize a model of pulmonary hypertension during chronic lung disease. The resulting device will be ready for pre- clinical testing. PUBLIC HEALTH RELEVANCE: The goal of this project is to design and test compliant artificial lungs. These devices will give chronic lung disease patients more time to find a donor lung and improve their health before and after transplantation.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Combined Use of Polycarboxybetaine Coatings with a Selective FXIIa Inhibitor to Create Potent Biomaterial Anticoagulation Without Bleeding During Extracorporeal Life Support
-
批准号:10444025
-
项目类别:
-
资助金额:$68.12万
-
财政年份:2022
-
负责人:Keith E Cook
-
依托单位:
Combined Use of Polycarboxybetaine Coatings with a Selective FXIIa Inhibitor to Create Potent Biomaterial Anticoagulation Without Bleeding During Extracorporeal Life Support
-
批准号:10743109
-
项目类别:
-
资助金额:$7.48万
-
财政年份:2022
-
负责人:Keith E Cook
-
依托单位:
Pulmonary Assist Device for Destination Therapy
-
批准号:9347492
-
项目类别:
-
资助金额:$22.43万
-
财政年份:2017
-
负责人:Keith E Cook
-
依托单位:
Antibacterial Perfluorocarbon Ventilation to Treat Severe Respiratory Infections
-
批准号:8461511
-
项目类别:
-
资助金额:$5.34万
-
财政年份:2012
-
负责人:Keith E Cook
-
依托单位:
Antibacterial Perfluorocarbon Ventilation to Treat Severe Respiratory Infections
-
批准号:8377155
-
项目类别:
-
资助金额:$7.78万
-
财政年份:2012
-
负责人:Keith E Cook
-
依托单位:
Antibacterial Perfluorocarbon Ventilation to Treat Severe Respiratory Infections
-
批准号:8819831
-
项目类别:
-
资助金额:$2.43万
-
财政年份:2012
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:7753676
-
项目类别:
-
资助金额:$36.94万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:8197545
-
项目类别:
-
资助金额:$35.69万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:7826231
-
项目类别:
-
资助金额:$2.17万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:9013492
-
项目类别:
-
资助金额:$63.92万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:7842072
-
项目类别:
-
资助金额:$25.64万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:9281151
-
项目类别:
-
资助金额:$4.63万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:8630703
-
项目类别:
-
资助金额:$44.73万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:7580398
-
项目类别:
-
资助金额:$36.28万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
Compliant Thoracic Artificial Lungs
-
批准号:8913761
-
项目类别:
-
资助金额:$61.16万
-
财政年份:2009
-
负责人:Keith E Cook
-
依托单位:
A Compact, Cardiopulmonary Support Device
-
批准号:7537048
-
项目类别:
-
资助金额:$16.22万
-
财政年份:2008
-
负责人:Keith E Cook
-
依托单位:
海外基金