Fabrication of a dual nano-biosensor for accurate sensitive and inexpensive elec
Fabrication of a dual nano-biosensor for accurate sensitive and inexpensive elec
批准号:
8253507
负责人:
Kosar baghbani Parizi
金额:
$61.14万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2012
资助国家:
美国
项目状态:
已结题
起止时间:
2012-09-01 至 2014-08-31
关键词:
AddressBase PairingBehaviorBiological SciencesBiosensorBuffersChargeClinicalDNADNA SequenceDataData Storage and RetrievalDetectionDiagnosticDiseaseElectronicsEnzymesEquipmentEventFeasibility StudiesFutureGenerationsGenomeGoalsIndustryInvestmentsIonic StrengthsLabelMeasuresMedicalMedicineNoiseOpticsPatientsPerformancePhasePreparationProcessPropertyReactionReagentReporterReportingResearchResearch InfrastructureResistanceSamplingSemiconductorsSignal TransductionSolutionsStratificationStructureSystemTechniquesTechnologyTestingTherapeuticTimeWorkaqueousbasecomputerized data processingcostdesigndisease diagnosisexperienceimprovedinnovationinstrumentationmodel designnanonanobiosensornanosensorsnext generationnovelpolymerizationprognosticresponsesensorsynthetic constructtool
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Advances in Next Generation Sequencing (NGS) have greatly accelerated fundamental life science research
but additional breakthroughs in technology are required to allow routine use of sequencing in the clinical setting
for personalized medicine as a disease diagnostic, prognostic and therapeutic tool and other applications.
Today's instrumentation and detection platforms allow sequencing of an entire genome for a cost of
approximately $10,000 requiring large up-front investment into expensive equipment. The current bottlenecks
include the use of expensive reagents and optical detection systems, large data storage and processing
requirements, slow sample preparation and turnaround times. Therefore, the overall goal is to develop a low
cost, real-time, fully-integrated sequencing system that encompasses the entire workflow and consists of
several innovative sample preparation and sequencing modules that are being developed in parallel.
One of the core components of the sequencing module will be two novel electric nano-biosensors that enable
label free, accurate and sensitive detection of the pH change as an 'electrical signature' of the polymerization
reaction during 'sequencing by synthesis' (SBS). Electronic sequencing offers several advantages over
pyrosequencing and other existing techniques as it does not require fluorescent labels or reporter enzymes
and optical detection systems. The innovative use of two independently operating electric nanosensors will
generate significantly more accurate sequencing data at lower cost, while reducing the need for highly
redundant sequence coverage.
Dual sensing mechanism of detecting both steady state signal (e.g. nanoneedle) and transient signal
(nanobridge) provides higher level of confidence and improves base calling accuracy, as two orthogonal
sensing mechanisms with the two sensors are reporting the same event. The overall goal for this proposal is to
demonstrate the feasibility of dual sensing for electronic DNA sequencing using the nanobridge and
nanoneedle biosensors and developing a design for the dual sensor detection module. Basic functional testing
and response to pH will be determined followed by a comparison of signal generation induced by pH changes
during 'sequencing by synthesis' polymerization reaction. In the first phase, we will work on the
characterization of nanobridge biosensor array, which is a depletion mode nano-resistor with low threshold and
large linear detection range and the comparison of the properties of the two nanosensors with respect to
response to pH or charge, buffer ionic strength and performance for DNA sequencing perspective. The results
from the feasibility study will provide the basis for the design and modeling of a dual sensor array in the future.