Millipede Percutaneous Annuloplasty Ring
Millipede Percutaneous Annuloplasty Ring
批准号:
8319331
负责人:
BRIAN BIANCUCCI
金额:
$58.46万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2010
资助国家:
美国
项目状态:
已结题
起止时间:
2010-07-20 至 2014-07-31
关键词:
AddressAnimalsCaliberCardiac Surgery proceduresCathetersChronicClinicalClinical TrialsContractsDevelopmentDevicesDiamondDimensionsDiseaseEnsureExhibitsFailureFamily suidaeFatigueFundingGoalsHeartHeart DiseasesHeart ValvesHumanImplantIn VitroLeadMethodsOperative Surgical ProceduresPatientsPatternPerformancePhasePositioning AttributeProceduresProcessPumpRadialSafetySecureSeriesShapesStentsStressSystemTechnologyTestingTissuesTricuspid Valve InsufficiencyTricuspid valve structurebasecommercializationdesignexperienceflexibilityimplantationimprovedin vivomillipedenitinolnovelpatient populationpre-clinicalpreventprototyperepairedtool
中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): Heart valve regurgitation is a serious condition related to heart disease. The most common and effective surgical method for treating this disease is with the use of an annuloplasty ring, which reduces the size of a dilated valve annulus to restore normal function. Many patients do not receive this procedure, however, either because they are too sick to undergo open heart surgery, or their condition has not yet progressed to the point at which surgery is justified. To address this large untreated patient population, many efforts have been undertaken to develop technology to repair leaky valves via catheter. Of these, the Millipede concept is the only device which can perform a true ring annuloplasty. This concept uses a ring that can both expand and contract under a radial force and has many small barbed anchors around its perimeter. After implant, a novel locking mechanism holds the ring at the desired diameter. The implantation process is performed by first inserting the delivery tool, an oversized wire "basket", into the annulus. This wire basket is larger than the annulus in diameter, but flexible enough to conform to the annular dimensions, which allows the user to "find" the annular tissue regardless of the size or shape of the annulus. Once placed in the annulus, the wires provide a series of rails, or delivery paths, over which the ring is delivered. The result is an automatic alignment of the ring and the annulus. Once aligned, a simple forward push of the ring drives the barbed anchors into the tissue and secures the ring in place. The basket is then contracted down and removed. In Phase II of this project we will surgically implant the prototypes developed in Phase I in animals. After developing a fully functional delivery system and conducting in vitro durability testing on the ring, we will perform percutaneous implants in animals.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Mitral Valve Repair Device
-
批准号:8055673
-
项目类别:
-
资助金额:$14.94万
-
财政年份:2011
-
负责人:BRIAN BIANCUCCI
-
依托单位:
Millipede Percutaneous Annuloplasty Ring
-
批准号:7999546
-
项目类别:
-
资助金额:$14.76万
-
财政年份:2010
-
负责人:BRIAN BIANCUCCI
-
依托单位:
Millipede Percutaneous Annuloplasty Ring
-
批准号:8198028
-
项目类别:
-
资助金额:$60.85万
-
财政年份:2010
-
负责人:BRIAN BIANCUCCI
-
依托单位:
Impeller optimization for a combined pump-oxygenator
-
批准号:7053458
-
项目类别:
-
资助金额:$20.0万
-
财政年份:2006
-
负责人:BRIAN BIANCUCCI
-
依托单位:
海外基金