课题基金 / 基金详情

4D Flow MRI-based assessment of atrial fibrillation

4D Flow MRI-based assessment of atrial fibrillation
基于 4D Flow MRI 的心房颤动评估
批准号:
10006579
负责人:
Liliana Ma
金额:
$5.05万
依托单位国家:
美国
项目类别:
财政年份:
2017
资助国家:
美国
项目状态:
已结题
起止时间:
2017-09-15 至 2021-09-14

项目摘要

项目成果

Liliana Ma的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Project Summary/abstract: Atrial fibrillation (AF) is the most common cardiac arrhythmia and estimated to account for approximately 15% of all strokes in the United States. Studies have shown that strokes in these patients seem to be caused by peripheral thromboembolisms which form in the left atrial appendage and travel to the brain. Anticoagulation has been shown to be highly effective at preventing thromboembolism formation, but is associated with greater monitoring costs and bleeding risks. Clinicians lack non-invasive diagnostic techniques that can reliably assess atrial hemodynamics, and current stroke prevention management relies on empirically determined risk scores that have been shown to have low predictive value. 4D flow magnetic resonance imaging provides time-resolved, three directional velocity encoding, but is currently limited by long scan times and inadequate resolution. In addition, the beat-to-beat variation of AF has not been considered in current MRI protocols that collect data over multiple cardiac cycles. This project aims to develop a 4D flow MRI protocol that incorporates improved temporal-spatial resolution, decreased scan time, and real-time MRI to more comprehensively assess atrial hemodynamics in AF patients. We will develop this protocol, assess repeatability and accuracy, and apply the protocol to a small study of AF patients and healthy volunteers.
期刊论文(9)
专著(0)
科研奖励(0)
会议论文
Development of a rotation phantom for phase contrast MRI sequence validation and quality control.
开发用于相差 MRI 序列验证和质量控制的旋转体模。
DOI: 10.1002/mrm.28343
发表时间: 2020
期刊: Magnetic resonance in medicine
影响因子: 3.3
作者: [Vali,Alireza, Schmitter,Sebastian, Ma,Liliana, Flassbeck,Sebastian, Schmidt,Simon, Markl,Michael, Schnell,Susanne]
通讯作者: Schnell,Susanne
DOI: 10.1002/mrm.28561
发表时间: 2021-04
期刊: Magnetic resonance in medicine
影响因子: 3.3
作者: [Pathrose A, Ma L, Berhane H, Scott MB, Chow K, Forman C, Jin N, Serhal A, Avery R, Carr J, Markl M]
通讯作者: Markl M
DOI: 10.1002/mrm.28642
发表时间: 2021-06
期刊: Magnetic resonance in medicine
影响因子: 3.3
作者: [Ma L, Yerly J, Di Sopra L, Piccini D, Lee J, DiCarlo A, Passman R, Greenland P, Kim D, Stuber M, Markl M]
通讯作者: Markl M
Comparison of Improved Unidirectional Dual Velocity-Encoding MRI Methods.
改进的单向双速度编码 MRI 方法的比较。
DOI: 10.1002/jmri.28305
发表时间: 2023
期刊: Journal of magnetic resonance imaging : JMRI
影响因子: --
作者: [Franco,Pamela, Ma,Liliana, Schnell,Susanne, Carrillo,Hugo, Montalba,Cristian, Markl,Michael, Bertoglio,Cristóbal, Uribe,Sergio]
通讯作者: Uribe,Sergio
4D Flow MRI-based assessment of atrial fibrillation
4D Flow MRI-based assessment of atrial fibrillation
海外基金