课题基金 / 基金详情

Aliquot-level visual indicators of biospecimen exposure to thawed conditions

Aliquot-level visual indicators of biospecimen exposure to thawed conditions
生物样本暴露于解冻条件下的等分水平视觉指示器
批准号:
10560579
负责人:
CHAD R BORGES
金额:
$17.98万
依托单位国家:
美国
项目类别:
财政年份:
2022
资助国家:
美国
项目状态:
未结题
起止时间:
2022-02-02 至 2025-01-31

项目摘要

项目成果

CHAD R BORGES的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Project Summary/Abstract Many biological analytes of interest to both clinical oncologists and cancer researchers are unstable when the unfixed biospecimens in which they reside are exposed to thawed conditions. For example, American Society of Clinical Oncology (ASCO)/College of American Pathologists (CAP) guidelines state that the post-excision- up-to-fixation exposure time span for tissues collected for clinical HER2 testing in breast cancer must be less than 1 hour. For blood plasma/serum and many types of tissue specimens that are to be frozen, the proper cold storage temperature is well below the common laboratory freezer temperature of -20 °C. For this and many other reasons, every year improprieties and inconsistencies in pre-analytical sample handling and storage generate unacceptably large numbers of costly false leads in biomedical research. Unsurprisingly, experts in the field agree that this problem must be minimized immediately. Currently there are few tools and not so much as one widely accepted approach by which to implement evidence-based tracking of biospecimen exposure to thawed conditions. In practice, it is actually quite rare for biomedical researchers to employ any evidence-based QA/QC tools at all—which suggests that easy-to-use, individual aliquot-level thawed-state indicators could have a major impact on improving biospecimen quality tracking and therefore actual quality. Here, we will develop color change-based indicators designed for 12 different biospecimen handling/storage requirements that ultimately will be implemented by placement into custom-designed dual-chambered, flex- activated (like a glow-stick) see-through devices that can be housed on (notched into) the outside of a specially designed sample storage vial. Once the bright pink color of permanganate (Mn(VII)) in the indicator turns clear due to its reduction to Mn(II) (as easily seen from the outside of the storage vial), this indicates that the specimen inside the vial has been exposed to a time-temperature span that is outside of the allowed storage/handling parameters. Importantly, subsets of these indicators will not freeze until -33.5 °C or -76 °C, facilitating the unprecedented ability to track exposures to very cold, but nevertheless improper storage temperatures—all in a manner that will be difficult to ignore by anyone handling the samples. Development of these indicators will be accomplished via two specific aims: Specific Aim 1: Establish kinetic control of the permanganate/oxalate reaction system by designing reaction starting conditions so that 12 uniquely useful time/temperature indicating solutions are developed. Specific Aim 2: Verify that reaction kinetics and temperature sensitivities for the 12 indicators behave as expected—that is, A) accurately, precisely (reproducibly), and with substantially increasing run times at 25 °C, 4 °C, 0 °C, and -20 °C—and B) remain accurate and precise when different stock solutions, reagent lots, analysts, or varying periods of freezing are involved.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Aliquot-level visual indicators of biospecimen exposure to thawed conditions
Plate reader assays to forensically assess exposure of plasma and serum to thawed conditions
Plate reader assays to forensically assess exposure of plasma and serum to thawed conditions
Validation and Advanced Development of Albumin Oxidizability as a Marker of Plasma/Serum Integrity
海外基金