BiVACOR - A Physiological, Durable and Blood-Friendly Total Artificial Heart
BiVACOR - A Physiological, Durable and Blood-Friendly Total Artificial Heart
批准号:
10620855
负责人:
Daniel Timms
金额:
$99.46万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2017
资助国家:
美国
项目状态:
已结题
起止时间:
2017-09-01 至 2024-04-30
关键词:
AffectAnatomyAnimalsBloodBlood flowCardiovascular DiseasesCase StudyCause of DeathChildClinicalDevelopmentDevice or Instrument DevelopmentDevicesDocumentationEligibility DeterminationEnvironmentEpidemicFDA approvedFailureFeasibility StudiesFreezingFriendsFutureGenerationsGoalsHealthHealth Care CostsHealthcare SystemsHeartHeart TransplantationHeart failureHospitalsHumanImplantIn VitroInstitutional Review BoardsInterventionInvestmentsKnowledgeLeftMagnetismManualsMechanicsMedicalMembraneMotorOrgan DonorOutcomeOutputPathway interactionsPatientsPerformancePhasePhysiologicalProceduresProductionPumpQuality of lifeSchemeSelf-Help DevicesSmall Business Innovation Research GrantSpeedSystemSystems IntegrationTechnologyTestingTransplantationUnited StatesVentricularWomanbiomaterial compatibilityblood pumpclinical applicationcommercial applicationcommercializationcostcourse developmentdesigneffective therapyfirst-in-humangood laboratory practicehemocompatibilityimprovedin vivoinnovationleft ventricular assist devicemanufacturemanufacturing processmechanical circulatory supportmenproduct developmentprogramssatisfactionsuccesstotal artificial hearttransplantation therapyventricular assist deviceverification and validation
中文摘要
摘要/文摘
英文摘要
SUMMARY/ABSTRACT
Heart Failure (HF) is a devastating epidemic affecting more than 23 million patients worldwide; in the U.S. alone,
1,000,000 new cases are reported each year. While heart transplantation provides the best treatment option for
many patients, less than 6,000 procedures take place globally each year. Consequently, it is estimated that
50,000 – 100,000 patients could immediately benefit from mechanical circulatory support.
Many circulatory support devices are available for patients who require left ventricular support, but few options
exist for patients who would benefit from biventricular support. With the exception of transplantation, the optimal
approach to biventricular failure is the replacement of the native heart with a Total Artificial Heart (TAH).
Traditional approaches have used volume displacement pumps, which have inherent limitations due to their
large size, flexing membranes, and valves that conspire to reduce the durability and lifetime of the device. The
same limitations were observed throughout the early application of VAD technology, which prompted a transition
to rotary blood pumps for size reduction and increased durability. Today, more than 60,000 patients are
supported with rotary VADs. Capitalizing on the advantages of rotary blood pump technology, the BiVACOR
TAH is small, reliable, blood-friendly and has inherently balanced blood flows.
Under the previous SBIR II, the implantable components of the BiVACOR TAH were significantly improved and
validated on the benchtop and in-vivo. Notable advancements were made in hemocompatibility, physiological
interaction, anatomical fit and reliability. BiVACOR is now entering the final product development and
manufacturing phase and wishes to utilize the SBIR IIB scheme to ready the BiVACOR TAH system for the first
clinical application via an FDA-approved Early Feasibility Study (EFS). In order to achieve this goal, the following
specific aims will be completed: 1) production of a clinical grade TAH system; 2) verification and validation,
including in-vivo studies under a Good Laboratory Practice environment, for regulatory approval; and 3)
submission of regulatory documentation for EFS. The commercial application and viability of this product will be
demonstrated and will encourage additional investment for full commercialization.
The world-wide impact of a commercially viable, long-term mechanical replacement to the failing human heart
will be tremendous. The wait for patients desperately requiring a heart transplant will go from years to off-the-
shelf availability, thereby quickly providing a vastly improved quality of life. Leveraging the successful durability
and small size of similar technologies used for ventricular assistance into the BiVACOR rotary TAH provides a
promising pathway to finally achieve the goal of a reliable, biocompatible, physiological, and ultimately practical
replacement to the failing human heart.
期刊论文(1)
专著(0)
科研奖励(0)
会议论文
The first clinical use of the BiVACOR Total Artificial Heart
-
批准号:10698258
-
项目类别:
-
资助金额:$156.95万
-
财政年份:2023
-
负责人:Daniel Timms
-
依托单位:
BiVACOR Rotary Total Artificial Heart
-
批准号:9410265
-
项目类别:
-
资助金额:$115.86万
-
财政年份:2017
-
负责人:Daniel Timms
-
依托单位:
BiVACOR - A Physiological, Durable and Blood-Friendly Total Artificial Heart
-
批准号:10402886
-
项目类别:
-
资助金额:$99.8万
-
财政年份:2017
-
负责人:Daniel Timms
-
依托单位:
BiVACOR - A Physiological, Durable and Blood-Friendly Total Artificial Heart
-
批准号:10214075
-
项目类别:
-
资助金额:$99.95万
-
财政年份:2017
-
负责人:Daniel Timms
-
依托单位:
海外基金