Optical Fluorescence and X-Ray Computed Tomography Scanner for Small Animal In-Vi
适用于小动物体内的光学荧光和 X 射线计算机断层扫描仪
基本信息
- 批准号:7910262
- 负责人:
- 金额:$ 10.27万
- 依托单位:
- 依托单位国家:美国
- 项目类别:
- 财政年份:2010
- 资助国家:美国
- 起止时间:2010-09-16 至 2011-06-15
- 项目状态:已结题
- 来源:
- 关键词:AlgorithmsAnatomic ModelsAnatomyAnimal ModelAnimalsAreaBiological MarkersBiological ProcessBiomedical ResearchCardiovascular DiseasesCell physiologyClinicCommunitiesComputer softwareDataDatabasesDevelopmentEffectivenessFluorescenceFuzzy LogicGoalsHemoglobinHistocompatibility TestingImageImaging PhantomsLasersLeadLearningLifeLightLiteratureLocationMalignant NeoplasmsMapsMeasurementMethodsMolecularMusOptical TomographyOpticsOrganPerformancePharmacotherapyPhasePreclinical Drug EvaluationProcessPropertyRelative (related person)ReporterResearchResolutionRoentgen RaysScanningSmall Animal Imaging SystemsSmall Business Innovation Research GrantSourceStagingSurfaceSystemTechniquesTechnologyTestingTissue ModelTissuesTomography, Computed, ScannersTranslationsX-Ray Computed TomographyX-Ray Computed Tomography ScannersX-Ray Tomographyaerobic respiration control proteinanticancer researchbasebiological systemsdesigndetectorfluorescence imaginghuman diseaseimage reconstructionimaging Segmentationimaging modalityimprovedin vivoinstrumentationinterestlight scatteringmouse modelnanoparticleneurological pathologypre-clinicalprototypepublic health relevancereconstructionresearch studysimulationtissue phantomtomographytooltwo-dimensional
项目摘要
DESCRIPTION (provided by applicant): The overall goal of this application is to develop a quantitative in-vivo small animal imaging system for fluorescent reporter probes that fuses fluorescence light emitting computed tomography (FLECT) with X- ray computed tomography (CT). The proposed dual-modality imaging system will not only provide a research tool for better understanding of biological function and processes on a cellular or molecular level in-vivo, but will also aid the development of new drug therapies and accelerate their translation into the clinic. Conventional imaging methods only provide two-dimensional (2D) fluorescence surface images and, hence, do not reveal the actual spatial location and concentration of the targeted reporter system. Furthermore, current fluorescence tomography (FT) systems are still in a developing stage and suffer from several limitations. First, these FT systems assume optically uniform tissue models that, consequently, prohibit the accurate quantification of the reporter probe's location and concentration. Second, neither planar fluorescence imaging nor FT provides any anatomical information. Hence, the reconstructed reporter probe location cannot be localized relative to the animal's anatomy. The proposed FLECT/CT system will overcome these limitations in two ways. First, we will leverage the anatomical information gained from CT with its high spatial resolution and assign optical properties to various segmented organs. These non-uniform optical property maps will in turn improve quantitative fluorescence image reconstruction leading to accurate images about the reporter probe's actual spatial location and concentration. Second, structural images from CT will provide the anatomical information that is necessary for co-locating the fluorescent reporter probe to the animal's anatomy. In Phase 1, we will perform numerical simulations and tissue phantom experiments that will provide a proof of principle for the proposed FLECT/CT system. We will demonstrate that (1) applying non-uniform optical property maps to FLECT reconstructions makes quantitative tomographic imaging of reporter probes feasible and (2) spatial maps of organs with largely varying optical properties can be segmented from CT images. In Phase 2, a commercial grade FLECT/CT system will be developed where the optical and X-ray components share the same rotating gantry. We will develop fully automated image segmentation methods and different techniques for assigning optical parameters to segmented organs. The optical parameters will be determined by (1) optical tomography in a reduced parameter space, (2) from known (oxy-)hemoglobin concentrations in different tissue types, or from (3) optical parameter databases of prior experiments. Last, the performance of the FLECT/CT system will be evaluated in small animal imaging experiments. Once completed, our FLECT/CT system will provide a powerful tool for research of cancer, neurological pathologies, and cardiovascular disease.
PUBLIC HEALTH RELEVANCE: The proposed development of a combined fluorescence tomography and X-ray CT imaging system for small animals will reconstruct and display the three-dimensional in-vivo distribution of fluorescent reporter probes for studying molecular processes in a living biological system. The combination of fluorescence tomography with X-ray CT will significantly improve the image quality of fluorescence tomographic images and will co-register them to structural CT images showing the animal's anatomy. Therefore, the proposed imaging system would not only be of great significance for better understanding biological processes and pathological function in living small animals on a cellular and molecular level, but would also aid the development of new drug therapies and accelerate their translation into the clinic.
描述(申请人提供):本申请的总体目标是开发一种用于荧光报告探针的定量体内小动物成像系统,该系统融合了荧光发射计算机断层扫描(FLECT)和X射线计算机断层扫描(CT)。拟议的双模式成像系统不仅将为在细胞或分子水平上更好地了解体内生物功能和过程提供研究工具,还将有助于开发新的药物疗法,并加速将其转化为临床。常规成像方法仅提供二维(2D)荧光表面图像,因此不能揭示靶向报告系统的实际空间位置和浓度。此外,目前的荧光层析成像(FT)系统仍处于发展阶段,并受到一些限制。首先,这些FT系统采用光学均匀的组织模型,因此无法准确量化报告探针的位置和浓度。其次,平面荧光成像和FT都不能提供任何解剖信息。因此,重建的报告探针位置不能相对于动物的解剖进行定位。拟议的Fect/CT系统将通过两种方式克服这些限制。首先,我们将利用从CT获得的高空间分辨率的解剖信息,并将光学属性分配给各个分段的器官。这些不均匀的光学性质图将反过来改进定量荧光图像重建,从而获得关于报告探测器的实际空间位置和浓度的准确图像。其次,来自CT的结构图像将提供将荧光报告探针共同定位到动物解剖所必需的解剖信息。在第一阶段,我们将进行数值模拟和组织模型实验,这将为拟议的Flect/CT系统提供原理证明。我们将证明:(1)将非均匀光学特性图应用于反射重建使报告探针的定量层析成像成为可能;(2)光学特性变化较大的器官的空间图可以从CT图像中分割出来。在第二阶段,将开发一种商业级Fect/CT系统,其中光学和X射线组件将共享同一旋转机架。我们将开发全自动图像分割方法和不同的技术来为分割的器官分配光学参数。光学参数将通过(1)简化参数空间中的光学层析成像、(2)根据不同组织类型中的已知(氧)血红蛋白浓度、或(3)先前实验的光学参数数据库来确定。最后,在小动物成像实验中对Fect/CT系统的性能进行了评估。一旦建成,我们的Flect/CT系统将为癌症、神经病理学和心血管疾病的研究提供强大的工具。
与公众健康相关:拟议开发的小动物荧光断层扫描和X射线CT成像系统将重建和显示荧光报告探针在体内的三维分布,用于研究活的生物系统中的分子过程。荧光断层成像和X射线CT的结合将显著提高荧光断层图像的图像质量,并将它们与显示动物解剖的结构CT图像共同配准。因此,所提出的成像系统不仅对于从细胞和分子水平更好地了解活的小动物的生物学过程和病理功能具有重要意义,而且将有助于新药疗法的开发和加速其转化为临床。
项目成果
期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)
数据更新时间:{{ journalArticles.updateTime }}
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ patent.updateTime }}
Seth D Shulman其他文献
Seth D Shulman的其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
{{ truncateString('Seth D Shulman', 18)}}的其他基金
Optical Fluorescence and X-Ray Computed Tomography Scanner for Small Animal In-Vi
适用于小动物体内的光学荧光和 X 射线计算机断层扫描仪
- 批准号:
8262437 - 财政年份:2010
- 资助金额:
$ 10.27万 - 项目类别:
Optical Fluorescence and X-Ray Computed Tomography Scanner for Small Animal In-Vi
适用于小动物体内的光学荧光和 X 射线计算机断层扫描仪
- 批准号:
8311635 - 财政年份:2010
- 资助金额:
$ 10.27万 - 项目类别: