Newer-Generation Ultrathin Strut Drug-Eluting Stents Versus Older Second-Generation Thicker Strut Drug-Eluting Stents for Coronary Artery Disease Meta-Analysis of Randomized Trials
Newer-Generation Ultrathin Strut Drug-Eluting Stents Versus Older Second-Generation Thicker Strut Drug-Eluting Stents for Coronary Artery Disease Meta-Analysis of Randomized Trials
复制标题
DOI:
10.1161/circulationaha.118.034456
复制
发表时间:
2018-11-13
期刊:
影响因子:
37.8
通讯作者:
Stone, Gregg W.
中科院分区:
文献类型:
--
作者:
Bangalore, Sripal;Toklu, Bora;Stone, Gregg W.
BACKGROUND: Contemporary second-generation drug-eluting stents (DES) have superior efficacy and safety in comparison with early-generation stents in patients undergoing percutaneous coronary intervention, in part, related to their thinner struts. Whether newer-generation ultrathin DES further improve clinical outcomes in comparison with older second-generation thicker strut DES is unknown.METHODS: We searched PubMed, Embase, and Cochrane Central Register of Controlled Trials for randomized clinical trials that compared newer-generation ultrathin strut DES (defined as strut thickness