Sirolimus-eluting biodegradable poly-L-lactide stent for peripheral vascular application:: A preliminary study in porcine carotid arteries
Sirolimus-eluting biodegradable poly-L-lactide stent for peripheral vascular application:: A preliminary study in porcine carotid arteries
复制标题
DOI:
10.1016/j.jss.2006.07.035
复制
发表时间:
2007-05-01
影响因子:
2.2
通讯作者:
Schareck, Wolfgang
中科院分区:
文献类型:
--
作者:
Buenger, Carsten Michael;Grabow, Niels;Schareck, Wolfgang
Background. To assess technical feasibility and biocompatibility of a new Sirolimus (SIIR.)-eluting biodegradable poly-L-lactide (PLIA) stent for peripheral vascular application.Material and methods. In 15 pigs,, both common carotid arteries (CCA) were surgically exposed and clamped in the proximal segment. After transverse incision, 12 316L stents, 12 unloaded and 6 SIR-loaded PLLA stents mounted on 6.0 X 40-mm balloon catheters were randomly implanted into the CCA and inflated to 8 bar. Angiographic equipment was not available. Stented CCA were explanted after 1 week (6 pigs; 316L versus PLIA) and 6 weeks (9 pigs; 316L versus PLIA versus SIR-PLIA), and processed for quantitative histomorphometry and estimation of vascular inflammation and injury scores.Results. No animals were lost during follow-up. All stents were patent on histological analysis without any signs of excessive recoiling or collapse. Unloaded PLLA stents showed decreased residual lumen area and increased neointimal area after 1 week (13.16 +/- 0.34, 1.94 +/- 0.26) and 6 weeks (11.57 +/- 0.30, 2.85 +/- 0.24) as compared with 316L stents (15.26 +/- 0.13, 1.27 +/- 0.41 and 13.99 +/- 0.51, 1.54 +/- 0.59). SIR-eluting stents demonstrated comparable neointimal area (1.75 +/- 0.38) and 50% lower intimal thickness as compared with 316L stents after 6 weeks, but a slightly decreased residual lumen (13.06 +/- 0.32) in the consequence of differences in strut thickness (PLLA, 270 mu m; 316L, 155 mu m). The vascular inflammation score against PLLA-stents could be reduced by Sirolimus. The vascular injury scores were low and similar in all groups.Conclusions. PLIA stents showed sufficient mechanical stability after porcine CCA stenting. By incorporation of Sirolimus, a significant reduction of the inflammatory and neointimal response to the PLIA stent was seen without systemic toxicity or thrombotic complications. These findings need to be assessed with longer follow-up to confirm maintenance of efficacy. The greater strut height of PLLA stents is a major limitation and requires modification. (c) 2007 Elsevier Inc. All rights reserved.