Use of Imugard IG500 Filters for Preparation of Leukocyte‐Poor Blood for Cancer Patients

Use of Imugard IG500 Filters for Preparation of Leukocyte‐Poor Blood for Cancer Patients
复制标题

使用 Imugard IG500 过滤器为癌症患者制备贫白细胞血液

DOI:
10.1111/j.1423-0410.1984.tb00065.x
复制
发表时间:
1984
期刊:
影响因子:
2.7
通讯作者:
J. Trujillo
J. Trujillo
中科院分区:
医学4区
文献类型:
--
作者:
B. Lichtiger;Luis Valle;Margie Armintor;J. Trujillo

文献摘要

被引文献

相似文献

In order to determine the efficiency of Imugard IG500 filters in producing leukocyte‐poor blood (LPB), 109 units of red cell concentrates were processed using cold (4°C) or room temperature saline solution without the application of pressure to the blood bag. The results obtained in terms of red blood cell recovery, white blood cell removal, residual white blood cells, and free hemoglobin in the supernatant of the filtered units are comparable to those processed with the IBM 2991. LPB processed without pressure application to the blood bag and room temperature saline solution can be rapidly, efficiently and safely prepared in any size blood bank/transfusion service. This technique is definitely cost‐saving in terms of equipment, software, space and personnel training.