A dosimetric comparison of copper and Cerrobend electron inserts.
A dosimetric comparison of copper and Cerrobend electron inserts.
复制标题
DOI:
10.1120/jacmp.v17i5.6282
复制
发表时间:
2016-09-08
影响因子:
2.1
通讯作者:
Hogstrom KR
中科院分区:
文献类型:
--
作者:
Rusk BD;Carver RL;Gibbons JP;Hogstrom KR
The purpose of this work was to evaluate differences in dose resulting from the use of copper aperture inserts compared to lead‐alloy (Cerrobend) aperture inserts for electron beam therapy. Specifically, this study examines if copper aperture inserts can be used clinically with the same commissioning data measured using lead‐alloy aperture inserts. The copper inserts were acquired from .decimal, LLC and matching lead‐alloy, Cerrobend inserts were constructed in‐house for 32 combinations of nine square insert field sizes ( to ) and five applicator sizes ( to ). Percent depth‐dose and off‐axis relative dose profiles were measured using an electron diode in water for select copper and Cerrobend inserts for a subset of applicators () and energies (6, 12, 20 MeV) at 100 and 110 cm source‐to‐surface distances (SSD) on a Varian Clinac 21EX accelerator. Dose outputs were measured for all field size‐insert combinations and five available energies () at 100 cm SSD and for a smaller subset at 110 cm SSD. Using these data, 2D planar absolute dose distributions were generated and compared. Criteria for agreement were of maximum dose or 1 mm distance‐to‐agreement for 99% of points. A gamma analysis of the beam dosimetry showed 94 of 96 combinations of insert size, applicator, energy, and SSD were within the criteria for of points. Outside the field, copper inserts showed less bremsstrahlung dose under the insert compared to Cerrobend (greatest difference was 2.5% at 20 MeV and 100 cm SSD). This effect was most prominent at the highest energies for combinations of large applicators with small field sizes, causing some gamma analysis failures. Inside the field, more electrons scattered from the collimator edge of copper compared to Cerrobend, resulting in an increased dose at the field edge for copper at shallow depths (greatest increase was 1% at 20 MeV and 100 cm SSD). Dose differences decreased as the SSD increased, with no gamma failures at 110 cm SSD. Inserts for field sizes at any energy, or for small fields () at energies , showed dosimetric differences less than for more than 99% of points. All areas of comparison criteria failures were from lower out‐of‐field dose under copper inserts due to a reduction in bremsstrahlung production, which is clinically beneficial in reducing dose to healthy tissue outside of the planned treatment volume. All field size‐applicator size‐energy combinations passed criteria for 100% of points. Therefore, it should be clinically acceptable to utilize copper insets with dose distributions measured with Cerrobend inserts for treatment planning dose calculations and monitor unit calculations. PACS number(s): 87.56.jk
登录
查看更多内容
DOI:
10.3109/02841868509134368
发表时间:
1985-01-01
期刊:
ACTA RADIOLOGICA ONCOLOGY
影响因子:
--
作者:
RIKNER, G
通讯作者:
RIKNER, G
影响因子:
3.8
作者:
Almond, PR;Biggs, PJ;Rogers, DWO
通讯作者:
Rogers, DWO
影响因子:
3.5
作者:
Gauer, T.;Sokoll, J.;Schmidt, R.
通讯作者:
Schmidt, R.
影响因子:
3.8
作者:
TENHAKEN, RK;FRAASS, BA;JOST, RJ
通讯作者:
JOST, RJ
DOI:
10.3109/02841868009130153
发表时间:
1980-01-01
期刊:
ACTA RADIOLOGICA ONCOLOGY
影响因子:
--
作者:
LAX, I;BRAHME, A
通讯作者:
BRAHME, A