VOLTAMMETRIC DETERMINATION OF PENTACHLOROPHENOL AT A GLASSY-CARBON ELECTRODE
VOLTAMMETRIC DETERMINATION OF PENTACHLOROPHENOL AT A GLASSY-CARBON ELECTRODE
复制标题
DOI:
10.1039/an9881300625
复制
发表时间:
1988-04-01
期刊:
影响因子:
4.2
通讯作者:
DIEZ, LMP
中科院分区:
文献类型:
--
作者:
GUIJARRO, EC;YANEZSEDENO, P;DIEZ, LMP
An electroanalytical study of the pentachlorophenol oxidation process at a glassy carbon electrode in aqueous solution using different voltammetric techniques has been carried out. The results obtained by differential-pulse voltammetry allowed a method to be developed for the determination of pentachlorophenol in the ranges 1.0 × 10–5–10.0 × 10–5 and 2.0 × 10–6–10.0 × 10–6 mol l–1, using ΔE= 50 mV. The coefficient of variation is 2.3% for a concentration of 5.0 × 10–5, mol l–1, with a limit of determination of 1.5 × 10–6 mol l–1 and a limit of detection of 4.5 × 10–7 mol l–1. The effect of other chlorophenols has been studied. Good results were obtained by applying the proposed differential-pulse voltammetric method to the determination of pentachlorophenol in a commercial fungicide.