MEASUREMENTS OF CALF LIVER ULTRASONIC DIFFERENTIAL AND TOTAL SCATTERING CROSS-SECTIONS
MEASUREMENTS OF CALF LIVER ULTRASONIC DIFFERENTIAL AND TOTAL SCATTERING CROSS-SECTIONS
复制标题
DOI:
10.1121/1.390534
复制
发表时间:
1984-01-01
影响因子:
2.4
通讯作者:
WAAG, RC
中科院分区:
文献类型:
--
作者:
CAMPBELL, JA;WAAG, RC
Ultrasonic scattering from calf liver was measured and normalized to obtain the average differential scattering cross section per unit volume [.hivin..sigma.sd (.nu.)] over scattering angles .nu. ranging in magnitude from 25.degree. to 165.degree. and frequencies between 3 and 7 MHz. At each of the measured frequencies, calf liver is a weak scatterer with nearly 1/2 of the total scattered power directed between 25.degree. and 45.degree.. The value of .hivin..sigma.sd (165.degree.), which is not expected to differ much from .hivin..sigma.sd (180.degree.), the backscattering coefficient, was .apprx. 3.7 .times. 10-6f1.4/mm per .OMEGA., with f in MHz and .OMEGA. in steradians. By integrating .hivin..sigma.sd over all the measured scattering angles to find the total scattering cross section .hivin..sigma.st, the contribution of scattering loss to attenuation was .apprx. 2% over the measured frequencies. Analysis of the shape of .hivin..sigma.sd suggests that the correlation length of the liver was on the order of 1 mm. To assess the accuracy of the normalization method, experimental and theoretical results for .hivin..sigma.st of a reference medium consisting of glass spheres in agar were compared and found to differ by < 10%.