Ultrasound-based transient elastography compared to magnetic resonance elastography in soft tissue-mimicking gels

Ultrasound-based transient elastography compared to magnetic resonance elastography in soft tissue-mimicking gels
复制标题

DOI:
10.1088/0031-9155/54/22/015
复制
发表时间:
2009-11-21
影响因子:
3.5
通讯作者:
Constantinesco, Andre
Constantinesco, Andre
中科院分区:
工程技术2区
文献类型:
--
作者:
Oudry, Jennifer;Vappou, Jonathan;Constantinesco, Andre

文献摘要

被引文献

相似文献

Ultrasound-based transient elastography (TE) and magnetic resonance elastography (MRE) are increasingly used methods for the clinical evaluation of soft tissue mechanical properties and their alteration under diseased conditions. This study proposes a comparison between magnetic resonance elastography (MRE) and ultrasound-based transient elastography (TE). Both methods were tested on the same soft tissue-mimicking gels in a common frequency range in order to allow for direct quantitative comparison. For the four gels tested, relatively good agreement was found between the shear moduli measured by both methods, with an averaged relative difference of 23%. This study demonstrates that under the assumption of homogeneous media that are significantly more elastic than viscous, quantitative results obtained by both methods are comparable.