Diagnosing metal fume fever-an integrated approach
Diagnosing metal fume fever-an integrated approach
复制标题
DOI:
10.1093/occmed/kqq036
复制
发表时间:
2010-08-01
影响因子:
5.1
通讯作者:
Fletcher, R. M.
中科院分区:
文献类型:
--
作者:
Cain, J. R.;Fletcher, R. M.
Background Exposure to high concentrations of zinc oxide fume can cause metal fume fever (MFF). Two cases occurring following the oxy-acetylene cutting of galvanized steel frames are reported.Aims To show that integrated working is valuable as secondary health care staff may not be familiar with MFF.Methods Site visits by Her Majesty's Medical, Health and Safety (H&S) and Specialist Occupational Hygiene Inspectors to gather information and cooperation with occupational health, primary and secondary health care staff to diagnose MFF.Results Poor exposure control caused metal fume inhalation in these cases. Multidisciplinary working established diagnosis, causation and compliance with H&S legislation.Conclusions Risk assessments are required to identify health risks and to determine required exposure control measures. Failure to do this resulted in an unusual case of MFF leading to hospital admission. Diagnosis can be delayed if a full occupational history is not taken. Successful investigation of such cases benefits from collaborative working.