Feasibility and validity of the ActiGraph GT3X accelerometer in measuring physical activity of Malawian toddlers
Feasibility and validity of the ActiGraph GT3X accelerometer in measuring physical activity of Malawian toddlers
复制标题
DOI:
10.1111/apa.12412
复制
发表时间:
2013-12-01
期刊:
影响因子:
3.8
通讯作者:
Ashom, P.
中科院分区:
文献类型:
--
作者:
Pulakka, A.;Cheung, Y. B.;Ashom, P.
Aim To test the feasibility and validity of the ActiGraph GT3X accelerometer in measuring physical activity of rural Malawian toddlers.Methods Fifty-six children aged 16.0-18.5months wore the accelerometer on their right hip for 7days. We analysed days with a minimum of 600min of wear time, excluding night time and periods when the unit registered zero for 20 consecutive minutes. The first and last days were excluded as they were incomplete. Accelerometer counts were compared with coded free play video recordings to define median accelerometer counts for sedentary, light, moderate and vigorous activity. Count cut points were defined for moderate to vigorous physical activity, with predictive validity assessed using a second set of video recordings.Results Median wear time was 797min/day, with 79% of participants completing at least four eligible days. Accelerometer counts were significantly higher for observed moderate to vigorous physical activity, than lighter activity, with cut points of 208 counts/15sec for vector magnitude and 35 counts/15sec for vertical axis, showing sensitivity of 94.2% and 84.1% and specificity of 90.9% and 84.6%, respectively.Conclusion The accelerometer proved a feasible and valid method of assessing physical activity among Malawian toddlers.