Quantitation of glaucomatous visual field defects with the Mark II Friedmann analyzer.

Quantitation of glaucomatous visual field defects with the Mark II Friedmann analyzer.
复制标题

使用 Mark II Friedmann 分析仪对青光眼视野缺陷进行定量。

DOI:
10.1016/0002-9394(83)90390-2
复制
发表时间:
1983
影响因子:
4.2
通讯作者:
D. R. Anderson
D. R. Anderson
中科院分区:
医学1区
文献类型:
--
作者:
B. Hicks;D. R. Anderson

文献摘要

参考文献

被引文献

相似文献

为了评估Friedmann视野分析仪确定视觉阈值和视野缺陷深度的能力,我们将动态确定的视觉阈值(Goldmann周长)与中央视野各个部分的静态阈值(Friedmann分析仪)相关联。我们发现以下内容:弗里德曼工作阈值与由戈德曼视野计的动态等线点的位置表示的视觉丘的高度线性相关;静态视觉阈值(弗里德曼)在一个特定的位置,无论是正常或异常,是线性相关的动态视觉阈值(Goldmann)在该位置;并且所有视野缺损的深度基本上与两种仪器相同。因此,Friedmann分析仪准确地定量了正常和异常区域的中心视野,并且可能有利于跟踪早期昏迷缺陷的进展。然而,对于其他患者,其有用性可能有限,因为无法记录25度以外的缺损,当定量不规则深度的大缺损时,视野检查可能冗长且效率低下,并且使用Friedmann分析仪的最大深度定量比使用Goldmann视野计在固定附近的深度定量低2.0 log单位(但对于距离固定更远的缺损,差异逐渐减小)。
To evaluate the ability of the Friedmann visual field analyzer to determine visual threshold and the depth of visual field defects, we correlated the visual threshold determined kinetically (Goldmann perimeter) with the static threshold (Friedmann analyzer) in various parts of the central field. We found the following: the Friedmann working threshold correlated linearly with the height of the hill of vision represented by the position of the kinetic isopters of the Goldmann perimeter; the static visual threshold (Friedmann) at a particular location, whether normal or abnormal, was linearly related to the kinetic visual threshold (Goldmann) at that location; and the depth of all visual field defects was essentially the same with both instruments.Thus, the Friedmann analyzer accurately quantitated the central visual field in both the normal and abnormal regions, and may be advantageous for following the progress of early glaucomatous defects. For other patients, however, its usefulness may be limited, because defects outside 25 degrees cannot be documented, the visual field examination may be lengthy and inefficient when quantitating large defects of irregular depth, and the maximal quantitation of depth with the Friedmann analyzer is 2.0 log units less than with the Goldmann perimeter near fixation (but there is progressively less difference for defects further from fixation).
使用弗里德曼分析仪与戈德曼周长仪比较来检测青光眼损伤并评估视神经盘的立体照片。
DOI: 10.1016/0002-9394(83)90262-3
发表时间: 1983
影响因子: 4.2
作者:
Batko,KA;Anctil,JL;Anderson,DR
通讯作者: Anderson,DR
DOI: --
发表时间: 1982
期刊: Transactions of the American Ophthalmological Society
影响因子: --
作者:
Anderson,DR
通讯作者: Anderson,DR
自动视野检查在青光眼视野进展中的有效性。
DOI: 10.1016/s0161-6420(82)34800-9
发表时间: 1982
期刊: Ophthalmology
影响因子: 13.7
作者:
Keltner,JL;Johnson,CA
通讯作者: Johnson,CA