Benchmarking energy consumption and CO2 emissions from rainwater‐harvesting systems: an improved method by proxy
Benchmarking energy consumption and CO2 emissions from rainwater‐harvesting systems: an improved method by proxy
复制标题
雨水收集系统的能源消耗和二氧化碳排放基准测试:一种改进的代理方法
DOI:
10.1111/j.1747-6593.2011.00279.x
复制
发表时间:
2012
影响因子:
2
通讯作者:
F. Memon
中科院分区:
文献类型:
--
作者:
S. Ward;D. Butler;F. Memon
Life cycle analyses (LCAs) show the main operational energy contribution for rainwater‐harvesting (RWH) systems come from ultraviolet (UV) disinfection and pumping rainwater from tank to building. Simple methods of estimating pump energy consumption do not differentiate between pump start‐up and pump‐operating energy or include pump efficiency parameters. This paper outlines an improved method incorporating these parameters that indirectly estimates pump energy consumption and carbon dioxide (CO2) emissions using system performance data. The improved method is applied to data from an office‐based RWH system. Comparison of the simple and improved methods identified the former underestimates pump energy consumption and carbon emissions by 60%. Results of the improved method corresponded well to directly measured energy consumption and energy consumption represented 0.07% of an office building's total energy consumption. Consequently, the overall energy consumption associated with RWH systems is a very minor fraction of total building energy consumption.