Lacrimal immunoglobulins and complement quantified by counter-immunoelectrophoresis.
Lacrimal immunoglobulins and complement quantified by counter-immunoelectrophoresis.
复制标题
通过反免疫电泳对泪液免疫球蛋白和补体进行定量。
DOI:
10.1136/bjo.59.5.279
复制
发表时间:
1975
影响因子:
4.1
通讯作者:
T. H. Pettit
中科院分区:
文献类型:
--
作者:
R. Bluestone;D. Easty;L. Goldberg;B. Jones;T. H. Pettit
Immunoglobulin and complement concentrations of tears were measured using a sensitive electroimmunodiffusion assay. In the 13 subjects tested, the predominant immunoglobulin was secretory IgA (mean concentration 107 mug/mg protein; standard error of mean 15; n equal 17). The B1C component of complement was measurable in half of the subjects studied. The data illustrate that it is possible to quantify exactly certain humoral indices which may be important in the host defense of the eye.