Effects of exhaust temperature on helicopter infrared signature
Effects of exhaust temperature on helicopter infrared signature
复制标题
DOI:
10.1016/j.applthermaleng.2012.09.016
复制
发表时间:
2013-03
影响因子:
6.4
通讯作者:
Pan Cheng-xiong;Zhang Jing-zhou;Shan Yong
中科院分区:
文献类型:
--
作者:
Pan Cheng-xiong;Zhang Jing-zhou;Shan Yong
The effects of exhaust temperature on infrared signature (in 3–5 μm band) for a helicopter equipped with integrative infrared suppressor were numerically investigated. The internal flow of exhaust gas and the external downwash flow, as well as the mixing between exhaust gas and downwash were simulated by CFD software to determine the temperature distributions on the helicopter skin and in the exhaust plume. Based on the skin and plume temperature distributions, a forward–backward ray-tracing method was used to calculate the infrared radiation intensity from the helicopter with a narrow-band model. The results show that for a helicopter with its integrative infrared suppressor embedded inside its rear airframe, the exhaust temperature has significant influence on the plume radiation characteristics, while the helicopter skin radiation intensity has little impact. When the exhaust temperature is raised from 900 K to 1200 K, the plume radiation intensity in 3–5 μm band is increased by about 100%, while the skin radiation intensity is increased by only about 5%. In general, the effects of exhaust temperature on helicopter infrared radiation intensity are mainly concentrated on plume, especially obvious for a lower skin emissivity case.