Contextualizing the revised Patient Perception of Patient-Centeredness (PPPC-R) scale in primary healthcare settings: a validity and reliability evaluation study.
Contextualizing the revised Patient Perception of Patient-Centeredness (PPPC-R) scale in primary healthcare settings: a validity and reliability evaluation study.
复制标题
将修订后的患者以患者为中心(PPPC-R)量表应用于初级保健环境:一项效度和可靠性评估研究。
DOI:
10.1186/s12875-023-02227-x
复制
发表时间:
2024-01-05
期刊:
影响因子:
--
通讯作者:
Xu, Dong (Roman)
中科院分区:
文献类型:
--
作者:
Cai, Yiyuan;Guo, Pengfei;Tu, Jiong;Hu, Mengyao;Liu, Lingrui;Ryan, Bridget L.;Liao, Jing;Dev, Rubee;Li, Yiran;Huang, Tianyu;Wang, Ruilin;Kuang, Li;Huang, Ruonan;Li, Xinfang;Melipillan, Edmundo Roberto;Zhao, Shuaixiang;He, Wenjun;Wang, Xiaohui;Zhang, Nan;Xu, Dong (Roman)
An English version of the Patient Perception of Patient-Centeredness (PPPC) scale was recently revised, and it is necessary to test this instrument in different primary care populations. This study aimed to assess the validity and reliability of a Chinese version of the PPPC scale. A mixed method was used in this study. The Delphi method was used to collect qualitative and quantitative data to address the content validity of the PPPC scale by calculating the Content Validity Index, Content Validity Ratio, the adjusted Kappa, and the Item Impact Score. Confirmatory factor analysis (CFA) and exploratory factor analysis (EFA) were used to assess the construct validity of the PPPC scale through a cross-sectional survey. The internal consistency was also assessed. In the Delphi consultation, seven experts were consulted through a questionnaire sent by email. The cross-sectional survey interviewed 188 outpatients in Guangzhou city and 108 outpatients in Hohhot City from community health service centers or stations face-to-face. The 21 items in the scale were relevant to their component. The Item-level Content Validity Index for each item was higher than 0.79, and the average Scale-level content validity index was 0.97 in each evaluation round. The initial proposed 4-factor CFA model did not fit adequately. Still, we found a 3-factor solution based on our EFA model and the validation via the CFA model (model fit: , P < 0.001, RMSEA = 0.044, CFI = 0.981; factor loadings: 0.553 to 0.888). Cronbach's α also indicated good internal consistency reliability: The overall Cronbach's α was 0.922, and the Cronbach's α for each factor was 0.851, 0.872, and 0.717, respectively. The Chinese version of the PPPC scale provides a valuable tool for evaluating patient-centered medical service quality. The online version contains supplementary material available at 10.1186/s12875-023-02227-x.
登录
查看更多内容
影响因子:
2.5
作者:
Rathert, Cheryl;Wyrwich, Mary D.;Boren, Suzanne Austin
通讯作者:
Boren, Suzanne Austin
影响因子:
2.7
作者:
Kimberlin, Carole L.;Winterstein, Almut G.
通讯作者:
Winterstein, Almut G.
影响因子:
3.5
作者:
Reinders, Marcel E.;Blankenstein, Annette H.;van Marwijk, Harm W. J.
通讯作者:
van Marwijk, Harm W. J.
影响因子:
3.9
作者:
Meredith, L;Stewart, M;Brown, JB
通讯作者:
Brown, JB
影响因子:
3.2
作者:
Nguyen Tu Ngoc;Ngangue, Patrice Alain;Fortin, Martin
通讯作者:
Fortin, Martin