Evaluation of a cefoxitin 30 microg disc on Iso-Sensitest agar for detection of methicillin-resistant Staphylococcus aureus.
Evaluation of a cefoxitin 30 microg disc on Iso-Sensitest agar for detection of methicillin-resistant Staphylococcus aureus.
复制标题
对 Iso-Sensitest 琼脂上的头孢西丁 30 微克圆片用于检测耐甲氧西林金黄色葡萄球菌的评估。
DOI:
--
复制
发表时间:
2003
影响因子:
5.2
通讯作者:
G. Kahlmeter
中科院分区:
文献类型:
--
作者:
R. Skov;R. Smyth;M. Clausen;A. Larsen;N. Frimodt;B. Olsson;G. Kahlmeter
OBJECTIVES
To evaluate the performance of a cefoxitin 30 microg disc on Iso-Sensitest agar, using a semi-confluent inoculum and overnight incubation at 35-36 degrees C, for detection of methicillin-resistant Staphylococcus aureus (MRSA).
METHODS
A total of 457 S. aureus, including 190 MRSA of several defined PFGE types and a number of low-level resistant isolates, were tested with a cefoxitin 30 microg disc on Iso-Sensitest agar, using a semi-confluent inoculum and overnight incubation at 35-36 degrees C. This method was compared with the standard SRGA (Swedish Reference Group for Antibiotics) method (oxacillin 1 microg disc on Iso-Sensitest agar supplemented with 5% defibrinated horse blood, confluent growth and 24 h incubation in ambient air at 30 degrees C).
RESULTS
The cefoxitin method was excellent, with a sensitivity of 100% and a specificity of 99% using an interpretative zone diameter of S > or = 29 mm and R < 29 mm. Its performance was much better than the SRGA method, which with this collection of difficult strains had a sensitivity of only 78% using the current breakpoint of S > or = 12 mm.
CONCLUSION
We suggest that the cefoxitin method should replace that currently recommended by the SRGA for the detection of MRSA, and that it would fit well into BSAC methodology.