Heat balance during plasma immersion ion implantation
Heat balance during plasma immersion ion implantation
复制标题
等离子体浸没离子注入过程中的热平衡
DOI:
--
复制
发表时间:
2001
期刊:
影响因子:
--
通讯作者:
B. Rauschenbach
中科院分区:
文献类型:
--
作者:
D. Manova;S. Mändl;B. Rauschenbach
The substrate temperature was measured during plasma immersion ion implantation (PIII) of nitrogen as a function of the pulse bias voltage and the repetition frequency. The variation of the equilibrium frequency for temperatures between 150 and 500 °C and pulse voltages between -5 and -30 kV was investigated. Using these data, the relative dose per pulse for different voltages was obtained and its voltage dependence compared with different models for the plasma sheath expansion during PIII. A higher plasma density than measured for a static plasma without pulses, due to the interaction of secondary electrons with the plasma, must be assumed. Good agreement with dose measurements of N implanted in Si was also observed. For high pulse frequencies above 1 kHz a deviation was observed, clearly showing that depletion of the ions from the plasma during the pulses leads to reduced average plasma density at high repetition rates.